Public manufacturer report

Coex 3D

Portfolio coverage, product-level engineering context and comparative public manufacturer positioning.

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:30

Public-data contract: portfolio statistics and positions use only explicitly allowlisted MaterialIDs and existing Verified Material Summary scores. No measurement or score is recalculated.
Public materials
5
Product lines
2
Material types
3
With results
5
Complete profiles
5
Average overall
46,8/100
Public global rank
1 of 11
Benchmark manufacturers
11

Manufacturer overview and public global position

MaterialsProduct linesTypesWith resultsCompleteAverage overallGlobal rankPortfolio leaderStrongest axisWith MSRPWith video
5235546,8/1001 of 11Coex 3D Standard Scarlet Red PLA Redstiffness50
Manufacturer website: Open manufacturer website

Category position by base material

Base materialPublic manufacturer positionAverage overallScored products
PCTG2 of 235/1001
PETG3 of 640/1001
PLA1 of 653/1003

Overall leaders

Coex 3D Standard Scarlet Red PLA Red
58/100
Coex 3D Prime Scarlet Red PLA Red
52/100
Coex 3D Standard Carbon Filled PLA CF Black
49/100
Coex 3D Standard Banana Yellow PETG Yellow
40/100
Coex 3D Prime Banany Yellow PCTG Yellow
35/100

Consistency leaders

Coex 3D Prime Scarlet Red PLA Red
88/100
Coex 3D Standard Scarlet Red PLA Red
86/100
Coex 3D Standard Carbon Filled PLA CF Black
77/100
Coex 3D Prime Banany Yellow PCTG Yellow
75/100
Coex 3D Standard Banana Yellow PETG Yellow
69/100

Product-level engineering context

MaterialIDMaterialProduct lineTypeReinforcementRigid coverageEngineering axesOverallTensileImpactIzodCharpyStiffnessConsistencyLayer adhesionStrongest axisMSRP USD/kgProductVideo
MAT0267Coex 3D Prime Banany Yellow PCTG YellowPrimePCTGComplete; 5/5 score families; Izod/Charpy 2/2 measured, 2/2 scored; Overall eligible; policy engineering-score-v70-17/835/10027/100—4/1001/10055/10075/10015/100consistency$0.19Product pagen/a
MAT0266Coex 3D Standard Banana Yellow PETG YellowStandardPETGComplete; 5/5 score families; Izod/Charpy 2/2 measured, 2/2 scored; Overall eligible; policy engineering-score-v70-17/840/10030/100—2/1001/10061/10069/10038/100consistency$0.19Product pagen/a
MAT0264Coex 3D Prime Scarlet Red PLA RedPrimePLAComplete; 5/5 score families; Izod/Charpy 2/2 measured, 2/2 scored; Overall eligible; policy engineering-score-v70-17/852/10034/100—5/1003/100100/10088/10032/100stiffness$0.28Product pagen/a
MAT0268Coex 3D Standard Carbon Filled PLA CF BlackStandardPLACFComplete; 5/5 score families; Izod/Charpy 2/2 measured, 2/2 scored; Overall eligible; policy engineering-score-v70-17/849/10032/100—6/10010/100100/10077/10030/100stiffness$0.22Product pagen/a
MAT0265Coex 3D Standard Scarlet Red PLA RedStandardPLAComplete; 5/5 score families; Izod/Charpy 2/2 measured, 2/2 scored; Overall eligible; policy engineering-score-v70-17/858/10039/100—4/1003/100100/10086/10061/100stiffness$0.24Product pagen/a
Results are comparative 3DPIceland measurements and do not replace manufacturer datasheets or accredited laboratory testing.

Testing methodology · Engineering methodology whitepaper · Download PDF

Coex 3D Prime Banany Yellow PCTG Yellow

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 1.1 kJ/m²; Std. Dev 0.043 kJ/m²; CV 3.916%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 2.826 kJ/m²; Std. Dev 0.773 kJ/m²; CV 27.357%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Coex 3D Standard Banana Yellow PETG Yellow

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.946 kJ/m²; Std. Dev 0.245 kJ/m²; CV 12.608%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 1.109 kJ/m²; Std. Dev 0.542 kJ/m²; CV 48.87%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Coex 3D Prime Scarlet Red PLA Red

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 2.277 kJ/m²; Std. Dev 0.053 kJ/m²; CV 2.346%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 3.754 kJ/m²; Std. Dev 0.222 kJ/m²; CV 5.914%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Coex 3D Standard Carbon Filled PLA CF Black

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 7.664 kJ/m²; Std. Dev 2.03 kJ/m²; CV 26.494%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 5.197 kJ/m²; Std. Dev 0.4 kJ/m²; CV 7.707%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Coex 3D Standard Scarlet Red PLA Red

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 2.659 kJ/m²; Std. Dev 0.373 kJ/m²; CV 14.039%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 3.198 kJ/m²; Std. Dev 0.186 kJ/m²; CV 5.808%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Score policy engineering-score-v70-1: Overall requires tensile, stiffness, consistency, layer adhesion and the Izod/Charpy impact family, each with equal weight. Both impact methods and configured versioned references are required. Missing results and unconfigured scores remain n/a. Legacy Impact is historical only; thermal remains separate. Engineering-axis counts describe displayed evidence, not Overall completeness.