Public engineering report

Prima Creator PrimaSelect ABS Blue

Material Engineering Report
MaterialID MAT0004
3DPIceland Engineering Platform
3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
Generated 2026-10-04 18:07:33
Public-data contract: This static report contains only allowlisted material identity, public links, canonical MSRP and existing Verified Material Summary / governed score outputs. It excludes raw specimen rows and non-public operational data.
Rigid test coverage
Partial; 4/5 score families; Izod/Charpy 0/2 measured, 0/2 scored; Overall unavailable: missing measurements or references; policy engineering-score-v70-1
Engineering axes
5/8
Public MSRP
$17.30 USD/kg

Material identity

MaterialIDMAT0004
MaterialPrima Creator PrimaSelect ABS Blue
ManufacturerPrima Creator
Product linePrimaSelect
Base materialABS
CategoryEngineering
Variant / finish—
Reinforcement—
ColorBlue

Governed engineering profile

Overall—
Tensile20/100
Impact—
Izod—
Charpy—
Stiffness68/100
Consistency57/100
Layer adhesion7/100
Thermal39/100
Best available axisstiffness

Engineering score profile

Overall
—
Tensile
20/100
Impact
—
Izod
—
Charpy
—
Stiffness
68/100
Consistency
57/100
Layer adhesion
7/100
Thermal
39/100

Engineering radar

TensileLegacy Impact %IzodCharpyStiffnessThermalLayer adhesionConsistency
Selected material
Material average - ABS
Manufacturer average - Prima Creator

Legacy Impact radar: 43.85 % of legacy rig capacity. This historical visual reference is the mean corrected Flat/Upright result divided by the matching rig capacity; it is not a modern engineering score.

Izod and Charpy use versioned method references and together form one equally weighted impact family. Overall requires all five families and both calibrated methods; incomplete profiles are not ranked. Legacy Impact and thermal are outside Overall. Missing axes have gaps with no marker or filled polygon; measured zero retains a centre marker.

Fixture thermal result

78 °C · score 39/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall———
Tensile20/10018/10027/100
Impact———
Izod—21/1008/100
Charpy—24/1008/100
Stiffness68/10070/10076/100
Consistency57/10068/10071/100
Layer adhesion7/10013/10022/100
Thermal39/100——

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright2.038 MPa1.315 MPa64.5%88/10
Tensile flat30.1 MPa5.616 MPa18.7%1010/10
Impact upright7.111 kJ/m²0.873 kJ/m²12.3%1010/10
Impact flat42.855 kJ/m²1.717 kJ/m²4%1010/10
Izod—————
Charpy—————
Stiffness modulus2027.607 MPa————
Stiffness deflection2.676 mm————

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
IzodNot recorded
CharpyNot recorded
StiffnessNot recorded
ThermalNot recorded

Engineering interpretation

Summary: Prima Creator PrimaSelect ABS Blue has a profile awaiting complete scoring evidence. It is without enough material-family average context and without enough manufacturer average context. Its strongest measured axis is Stiffness, while the weakest axis is Layer Adhesion.
Data-driven review: Prima Creator PrimaSelect ABS Blue has incomplete scoring evidence or pending method references. Overall suitability and ranking are unavailable. Available scored axes can be inspected separately; missing scores do not establish weak material performance.
Best feature
Stiffness
Main limitation
Layer Adhesion
Dataset position
—
—

Strengths

  • Best available signal: Stiffness at 68/100.

Limitations

  • Tensile: 20/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Consistency: 57/100. Repeatability may not be the best reason to choose this filament.
  • Layer adhesion: 7/100. Z-axis performance should be treated with caution.

Engineering trade-offs

  • Complete scoring evidence and approved method references are required before assessing an overall balance of properties.

Recommended applications

  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications

Metric rankings and percentiles

MetricScoreRankPercentile
Overall———
Tensile20/100200 / 243Better than 18%
Impact———
Izod———
Charpy———
Stiffness68/100168 / 240Better than 30%
Consistency57/100228 / 243Better than 7%
Layer adhesion7/100236 / 243Better than 3%
Thermal39/10058 / 226Better than 75%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
No stronger same-base-material alternatives were identified in the current governed dataset.

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
MAT0246Bedrock 3D Standard Black ABS Plus BlackBedrock 3D46/10014/100—n/an/a
MAT0207Siraya Tech Fiberheart Black ABS Core CF BlackSiraya Tech46/10024/100—n/an/a
MAT0199Siraya Tech Fiberheart Black ABS CF BlackSiraya Tech41/10022/100—n/an/a
MAT0180BambuLab Standard White ABS GF WhiteBambuLab40/10018/100—n/an/a
MAT0201Siraya Tech Fiberheart Gray ABS GF GraySiraya Tech38/10017/100—n/an/a
MAT0002Extrudr DuraPro ABS CF BlackExtrudr37/1005/100—n/an/a
MAT0181BambuLab Standard Blue ABS BlueBambuLab—19/100—n/an/a
MAT0208Eryone Standard White ABS WhiteEryone———n/an/a

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.