3DPIceland Engineering Platform 3DPIceland Labs Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology Generated 2026-10-04 18:07:33
Public-data contract: This static report contains only allowlisted material identity, public links, canonical MSRP and existing Verified Material Summary / governed score outputs. It excludes raw specimen rows and non-public operational data.
Legacy Impact radar: 19.805 % of legacy rig capacity. This historical visual reference is the mean corrected Flat/Upright result divided by the matching rig capacity; it is not a modern engineering score.
Izod and Charpy use versioned method references and together form one equally weighted impact family. Overall requires all five families and both calibrated methods; incomplete profiles are not ranked. Legacy Impact and thermal are outside Overall. Missing axes have gaps with no marker or filled polygon; measured zero retains a centre marker.
Fixture thermal result
62 °C · score 31/100 · method 3dp-thermal-deflection-fixture-v1 Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.
Material and manufacturer context
Metric
Selected material
Material average
Manufacturer average
Overall
—
—
—
Tensile
29/100
28/100
27/100
Impact
—
—
—
Izod
—
5/100
8/100
Charpy
—
4/100
8/100
Stiffness
52/100
60/100
76/100
Consistency
70/100
74/100
71/100
Layer adhesion
40/100
31/100
22/100
Thermal
31/100
—
—
Verified measurement results
Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.
Measurement
Average
Std. deviation
CV
Samples
Confidence
Tensile upright
13.12 MPa
5.784 MPa
44.1%
10
10/10
Tensile flat
33.1 MPa
5.555 MPa
16.8%
10
10/10
Impact upright
7.894 kJ/m²
1.23 kJ/m²
15.6%
10
10/10
Impact flat
14.672 kJ/m²
2.766 kJ/m²
18.9%
10
10/10
Izod
—
—
—
—
—
Charpy
—
—
—
—
—
Stiffness modulus
1563.663 MPa
—
—
—
—
Stiffness deflection
3.47 mm
—
—
—
—
Measurement provenance
Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.
Module
Measured date
Tensile
Not recorded
Impact
Not recorded
Izod
Not recorded
Charpy
Not recorded
Stiffness
Not recorded
Thermal
Not recorded
Engineering interpretation
Summary: Prima Creator PrimaSelect Lake Blue PETG Blue has a profile awaiting complete scoring evidence. It is without enough material-family average context and without enough manufacturer average context. Its strongest measured axis is Consistency, while the weakest axis is Tensile.
Data-driven review: Prima Creator PrimaSelect Lake Blue PETG Blue has incomplete scoring evidence or pending method references. Overall suitability and ranking are unavailable. Available scored axes can be inspected separately; missing scores do not establish weak material performance.
Best feature
Consistency
Main limitation
Tensile
Dataset position
—
—
Strengths
Layer adhesion: 40/100. Z-axis bonding is better than the material-family context.
Limitations
Tensile: 29/100. Avoid using this as the primary choice for tensile-loaded parts.
Layer adhesion: 40/100. Z-axis performance should be treated with caution.
Engineering trade-offs
Good repeatability does not compensate for low tensile capability in load-bearing designs.
Recommended applications
Cosmetic parts, concept models or low-load prototypes
Avoid high tensile load applications
Metric rankings and percentiles
Metric
Score
Rank
Percentile
Overall
—
—
—
Tensile
29/100
123 / 243
Better than 50%
Impact
—
—
—
Izod
—
—
—
Charpy
—
—
—
Stiffness
52/100
214 / 240
Better than 11%
Consistency
70/100
177 / 243
Better than 28%
Layer adhesion
40/100
51 / 243
Better than 79%
Thermal
31/100
100 / 226
Better than 56%
Decision guidance
Overall suitability is unavailable until the required measurements and method references are complete.
Do not choose it as a tensile-strength benchmark material.
Better alternatives
MaterialID
Material
Manufacturer
Overall
Tensile
Impact
Izod
Charpy
No stronger same-base-material alternatives were identified in the current governed dataset.
Peer context
Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.
Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.