Public engineering report

Atomic Standard PETG Blue

Material Engineering Report
MaterialID MAT0051
3DPIceland Engineering Platform
3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
Generated 2026-10-04 18:07:33
Public-data contract: This static report contains only allowlisted material identity, public links, canonical MSRP and existing Verified Material Summary / governed score outputs. It excludes raw specimen rows and non-public operational data.
Rigid test coverage
Partial; 4/5 score families; Izod/Charpy 0/2 measured, 0/2 scored; Overall unavailable: missing measurements or references; policy engineering-score-v70-1
Engineering axes
5/8
Public MSRP
$32.99 USD/kg

Material identity

MaterialIDMAT0051
MaterialAtomic Standard PETG Blue
ManufacturerAtomic
Product lineStandard
Base materialPETG
CategoryStandard
Variant / finish—
Reinforcement—
ColorBlue

Governed engineering profile

Overall—
Tensile24/100
Impact—
Izod—
Charpy—
Stiffness42/100
Consistency82/100
Layer adhesion47/100
Thermal31/100
Best available axisconsistency

Engineering score profile

Overall
—
Tensile
24/100
Impact
—
Izod
—
Charpy
—
Stiffness
42/100
Consistency
82/100
Layer adhesion
47/100
Thermal
31/100

Engineering radar

TensileLegacy Impact %IzodCharpyStiffnessThermalLayer adhesionConsistency
Selected material
Material average - PETG
Manufacturer average - Atomic

Legacy Impact radar: 11.918 % of legacy rig capacity. This historical visual reference is the mean corrected Flat/Upright result divided by the matching rig capacity; it is not a modern engineering score.

Izod and Charpy use versioned method references and together form one equally weighted impact family. Overall requires all five families and both calibrated methods; incomplete profiles are not ranked. Legacy Impact and thermal are outside Overall. Missing axes have gaps with no marker or filled polygon; measured zero retains a centre marker.

Fixture thermal result

62 °C · score 31/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall———
Tensile24/10028/10024/100
Impact———
Izod—5/100—
Charpy—4/100—
Stiffness42/10060/10042/100
Consistency82/10074/10082/100
Layer adhesion47/10031/10047/100
Thermal31/100——

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright12.028 MPa2.398 MPa19.9%1010/10
Tensile flat25.655 MPa4.066 MPa15.8%1010/10
Impact upright1.645 kJ/m²0.443 kJ/m²27%1010/10
Impact flat11.936 kJ/m²4.623 kJ/m²38.7%1010/10
Izod—————
Charpy—————
Stiffness modulus1272.498 MPa————
Stiffness deflection4.265 mm————

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
IzodNot recorded
CharpyNot recorded
StiffnessNot recorded
ThermalNot recorded

Engineering interpretation

Summary: Atomic Standard PETG Blue has a profile awaiting complete scoring evidence. It is without enough material-family average context and without enough manufacturer average context. Its strongest measured axis is Consistency, while the weakest axis is Tensile.
Data-driven review: Atomic Standard PETG Blue has incomplete scoring evidence or pending method references. Overall suitability and ranking are unavailable. Available scored axes can be inspected separately; missing scores do not establish weak material performance.
Best feature
Consistency
Main limitation
Tensile
Dataset position
—
—

Strengths

  • Layer adhesion: 47/100. Z-axis bonding is better than the material-family context.
  • Consistency: 82/100. Repeatability is one of the stronger signals in this material profile.

Limitations

  • Tensile: 24/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Stiffness: 42/100. Expect less shape stability than the stronger materials in the same family.

Engineering trade-offs

  • Good repeatability does not compensate for low tensile capability in load-bearing designs.

Recommended applications

  • Repeatable print jobs and production-style batches
  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications

Metric rankings and percentiles

MetricScoreRankPercentile
Overall———
Tensile24/100171 / 243Better than 30%
Impact———
Izod———
Charpy———
Stiffness42/100228 / 240Better than 5%
Consistency82/10051 / 243Better than 79%
Layer adhesion47/10027 / 243Better than 89%
Thermal31/100100 / 226Better than 56%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
No stronger same-base-material alternatives were identified in the current governed dataset.

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
MAT0236Yasin Standard Black PETG CF BlackYasin47/10030/100—n/an/a
MAT0198Siraya Tech Fiberheart Black PETG Pro CF BlackSiraya Tech46/10033/100—n/an/a
MAT0235Yasin Standard Black PETG GF BlackYasin44/10027/100—n/an/a
MAT0048Prusa3D Prusament Jet Black PETG V0 BlackPrusa3D44/10026/100—n/an/a
MAT0042Prusa3D Prusament PETG CF BlackPrusa3D42/10025/100—n/an/a
MAT0043Prima Creator PrimaSelect PETG GF WhitePrima Creator40/10031/100—n/an/a
MAT0266Coex 3D Standard Banana Yellow PETG YellowCoex 3D40/10030/100—n/an/a
MAT0061Prusa3D Prusament Signal White PETG WhitePrusa3D39/10033/100—n/an/a

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.