Public engineering report

Winkle Standard Winkle Purple PLA HD Purple

Material Engineering Report
MaterialID MAT0162
3DPIceland Engineering Platform
3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
Generated 2026-10-04 18:07:33
Public-data contract: This static report contains only allowlisted material identity, public links, canonical MSRP and existing Verified Material Summary / governed score outputs. It excludes raw specimen rows and non-public operational data.
Rigid test coverage
Partial; 4/5 score families; Izod/Charpy 0/2 measured, 0/2 scored; Overall unavailable: missing measurements or references; policy engineering-score-v70-1
Engineering axes
5/8
Public MSRP
$39.96 USD/kg

Material identity

MaterialIDMAT0162
MaterialWinkle Standard Winkle Purple PLA HD Purple
ManufacturerWinkle
Product lineStandard
Base materialPLA
CategoryStandard
Variant / finishHD
Reinforcement—
ColorPurple

Governed engineering profile

Overall—
Tensile34/100
Impact—
Izod—
Charpy—
Stiffness100/100
Consistency67/100
Layer adhesion33/100
Thermal26/100
Best available axisstiffness

Engineering score profile

Overall
—
Tensile
34/100
Impact
—
Izod
—
Charpy
—
Stiffness
100/100
Consistency
67/100
Layer adhesion
33/100
Thermal
26/100

Engineering radar

TensileLegacy Impact %IzodCharpyStiffnessThermalLayer adhesionConsistency
Selected material
Material average - PLA
Manufacturer average - Winkle

Legacy Impact radar: 15.529 % of legacy rig capacity. This historical visual reference is the mean corrected Flat/Upright result divided by the matching rig capacity; it is not a modern engineering score.

Izod and Charpy use versioned method references and together form one equally weighted impact family. Overall requires all five families and both calibrated methods; incomplete profiles are not ranked. Legacy Impact and thermal are outside Overall. Missing axes have gaps with no marker or filled polygon; measured zero retains a centre marker.

Fixture thermal result

52 °C · score 26/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall———
Tensile34/10030/10031/100
Impact———
Izod—8/100—
Charpy—10/100—
Stiffness100/10087/10085/100
Consistency67/10075/10074/100
Layer adhesion33/10031/10033/100
Thermal26/100——

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright13.504 MPa6.292 MPa46.6%1010/10
Tensile flat41.236 MPa8.177 MPa19.8%1010/10
Impact upright6.33 kJ/m²0.868 kJ/m²13.7%1010/10
Impact flat11.366 kJ/m²1.151 kJ/m²10.1%1010/10
Izod—————
Charpy—————
Stiffness modulus3000.199 MPa————
Stiffness deflection1.809 mm————

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
IzodNot recorded
CharpyNot recorded
StiffnessNot recorded
Thermal2026-08-25

Engineering interpretation

Summary: Winkle Standard Winkle Purple PLA HD Purple has a profile awaiting complete scoring evidence. It is without enough material-family average context and without enough manufacturer average context. Its strongest measured axis is Stiffness, while the weakest axis is Thermal.
Data-driven review: Winkle Standard Winkle Purple PLA HD Purple has incomplete scoring evidence or pending method references. Overall suitability and ranking are unavailable. Available scored axes can be inspected separately; missing scores do not establish weak material performance.
Best feature
Stiffness
Main limitation
Thermal
Dataset position
—
—

Strengths

  • Stiffness: 100/100. Stiffness is a relative advantage in this comparison group.

Limitations

  • Tensile: 34/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Layer adhesion: 33/100. Z-axis performance should be treated with caution.

Engineering trade-offs

  • Good repeatability does not compensate for low tensile capability in load-bearing designs.

Recommended applications

  • Rigid brackets, fixtures and shape-stable prototypes
  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications

Metric rankings and percentiles

MetricScoreRankPercentile
Overall———
Tensile34/10057 / 243Better than 77%
Impact———
Izod———
Charpy———
Stiffness100/1001 / 240Better than 100%
Consistency67/100198 / 243Better than 19%
Layer adhesion33/10077 / 243Better than 69%
Thermal26/100168 / 226Better than 26%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
No stronger same-base-material alternatives were identified in the current governed dataset.

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
MAT0265Coex 3D Standard Scarlet Red PLA RedCoex 3D58/10039/100—n/an/a
MAT0118Prusa3D Prusament Azure Blue PLA BluePrusa3D55/10036/100—n/an/a
MAT0112Prusa3D Prusament Galaxy Black PLA BlackPrusa3D52/10038/100—n/an/a
MAT0143Prusa3D Prusament Corn Pigment PLA Recycled BrownPrusa3D52/10030/100—n/an/a
MAT0203Prusa3D Prusament Prusa Orange PLA OrangePrusa3D52/10042/100—n/an/a
MAT0264Coex 3D Prime Scarlet Red PLA RedCoex 3D52/10034/100—n/an/a
MAT0205Prusa3D Prusament Marble Gray PLA Marble GrayPrusa3D51/10037/100—n/an/a
MAT0204Prusa3D Prusament Jet Black PLA BlackPrusa3D51/10040/100—n/an/a

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.