Siraya Tech Fiberheart Black TPU 67D GF Black

Material Engineering Report
MaterialID MAT0200
3DPIceland Engineering Platform
3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
Generated 2026-10-04 18:07:33
Public-data contract: This static report contains only allowlisted material identity, public links, canonical MSRP and existing Verified Material Summary / governed score outputs. It excludes raw specimen rows and non-public operational data.
Rigid test coverage
Partial; 4/5 score families; Izod/Charpy 2/2 measured, 2/2 scored; Overall unavailable: missing measurements or references; policy engineering-score-v70-1
Engineering axes
6/8
Public MSRP
$35.19 USD/kg

Material identity

MaterialIDMAT0200
MaterialSiraya Tech Fiberheart Black TPU 67D GF Black
ManufacturerSiraya Tech
Product lineFiberheart
Base materialTPU
CategoryFlexible
Variant / finish67D
ReinforcementGF
ColorBlack

Governed engineering profile

Overall—
Tensile27/100
Impact—
Izod48/100
Charpy47/100
Stiffness—
Consistency92/100
Layer adhesion25/100
Thermal56/100
Best available axisconsistency

Engineering score profile

Overall
—
Tensile
27/100
Impact
—
Izod
48/100
Charpy
47/100
Stiffness
—
Consistency
92/100
Layer adhesion
25/100
Thermal
56/100

Engineering radar

TensileLegacy Impact %IzodCharpyStiffnessThermalLayer adhesionConsistency
Selected material
Material average - TPU
Manufacturer average - Siraya Tech

Legacy Impact radar: 61.705 % of legacy rig capacity. This historical visual reference is the mean corrected Flat/Upright result divided by the matching rig capacity; it is not a modern engineering score.

Izod and Charpy use versioned method references and together form one equally weighted impact family. Overall requires all five families and both calibrated methods; incomplete profiles are not ranked. Legacy Impact and thermal are outside Overall. Missing axes have gaps with no marker or filled polygon; measured zero retains a centre marker.

Fixture thermal result

111 °C · score 56/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall———
Tensile27/10027/10026/100
Impact———
Izod48/10048/10015/100
Charpy47/10047/10019/100
Stiffness——86/100
Consistency92/10092/10079/100
Layer adhesion25/10025/10016/100
Thermal56/100——

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright8.736 MPa1.672 MPa19.1%1010/10
Tensile flat34.73 MPa1.932 MPa5.6%1010/10
Impact upright14.51 kJ/m²0.998 kJ/m²6.9%1010/10
Impact flat55.801 kJ/m²1.537 kJ/m²2.8%1010/10
Izod38.345 kJ/m²2.077 kJ/m²5.4%1010/10
Charpy37.801 kJ/m²0.917 kJ/m²2.4%1010/10
Stiffness modulus—————
Stiffness deflection—————

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
Tensile0202-01-01
ImpactNot recorded
Izod2026-10-04
Charpy2026-10-04
StiffnessNot recorded
ThermalNot recorded

Engineering interpretation

Summary: Siraya Tech Fiberheart Black TPU 67D GF Black has a profile awaiting complete scoring evidence. It is without enough material-family average context and without enough manufacturer average context. Its strongest measured axis is Consistency, while the weakest axis is Layer Adhesion.
Data-driven review: Siraya Tech Fiberheart Black TPU 67D GF Black has incomplete scoring evidence or pending method references. Overall suitability and ranking are unavailable. Available scored axes can be inspected separately; missing scores do not establish weak material performance.
Best feature
Consistency
Main limitation
Layer Adhesion
Dataset position
—
—

Strengths

  • Consistency: 92/100. Repeatability is one of the stronger signals in this material profile.

Limitations

  • Tensile: 27/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Layer adhesion: 25/100. Z-axis performance should be treated with caution.

Engineering trade-offs

  • Good repeatability does not compensate for low tensile capability in load-bearing designs.

Recommended applications

  • Repeatable print jobs and production-style batches
  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications

Metric rankings and percentiles

MetricScoreRankPercentile
Overall———
Tensile27/100139 / 243Better than 43%
Impact———
Izod48/1002 / 83Better than 99%
Charpy47/1004 / 82Better than 96%
Stiffness———
Consistency92/1003 / 243Better than 99%
Layer adhesion25/100112 / 243Better than 54%
Thermal56/10013 / 226Better than 95%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
No stronger same-base-material alternatives were identified in the current governed dataset.

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
MAT0253Bedrock 3D Standard Black TPU 64D BlackBedrock 3D———n/an/a
MAT0256Bedrock 3D Standard Black TPU Foaming BlackBedrock 3D———n/an/a
MAT0255Bedrock 3D Standard Natural TPU 85A NaturalBedrock 3D———n/an/a
MAT0254Bedrock 3D Standard White TPU 95A WhiteBedrock 3D———n/an/a
MAT0257Prima Creator Select Black TPU BlackPrima Creator———n/an/a
MAT0261Prusa3D Prusament Jet Black TPU 95A BlackPrusa3D———n/an/a
MAT0260Thorwell Standard Blue TPU BlueThorwell———n/an/a

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.

Flexible Material Testing

Comparative in-house measurements; n = independent specimens. Separate test groups; Overall unchanged.

MethodResultConditionMeannSDCV %RangeNot reached
3ef3953fApparent Compressive Stress at 20% Strain (MPa)10 s hold · 2 mm displacement · cycle 14.28270.1864.3323.977–4.5590
3ef3953fApparent Compressive Stress at 20% Strain (MPa)30 s hold · 2 mm displacement · cycle 13.94570.1674.2413.663–4.1810
3ef3953fCompression Force at 20% Strain (N)10 s hold · 2 mm displacement · cycle 1272.429711.8024.332253–2900
3ef3953fCompression Force at 20% Strain (N)30 s hold · 2 mm displacement · cycle 1251710.6464.241233–2660
3ef3953fForce reduction from 10 s to 30 s at 20% Strain (%)first compression only · 2 mm displacement7.86370.2833.5967.463–8.2760
3ef3953fForce retention at 20% Strain (%)10–30 s · 2 mm displacement · cycle 192.13770.2830.30791.724–92.5370
3ef3953fResidual height loss after recovery (%)20% compression · 30 s compressed hold · 60 s rest · 10 mm initial height · cycle 12.56760.33312.9612.1–30
ed381ba8Shore A Hardness (Shore A)10 s reading · 8 mm91.41——91.4–91.40

Shore location statistics

Within each specimen; specimen numbers are local to each test group. SD uses the sample formula. These readings do not increase independent n.

MethodScaleConditionSpecimenReadingsMeanLocation SDLocation CV %
ed381ba8Shore A Hardness10 s reading · 8 mm1591.41.8171.988

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 38.345 kJ/m²; Std. Dev 2.077 kJ/m²; CV 5.417%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 37.801 kJ/m²; Std. Dev 0.917 kJ/m²; CV 2.426%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.