Public engineering report

Eryone Standard Black PA6 GF Black

Material Engineering Report
MaterialID MAT0210
3DPIceland Engineering Platform
3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
Generated 2026-08-25 19:02:26
Public-data contract: This static report contains only allowlisted material identity, public links, canonical MSRP and existing Verified Material Summary / governed score outputs. It excludes raw specimen rows and non-public operational data.
Test coverage
Partial
Engineering axes
4/6
Public MSRP
$25.00 USD/kg

Material identity

MaterialIDMAT0210
MaterialEryone Standard Black PA6 GF Black
ManufacturerEryone
Product lineStandard
Base materialPA6
CategoryEngineering
Variant / finish
ReinforcementGF
ColorBlack

Governed engineering profile

Overall72/100
Tensile
Impact40/100
Stiffness100/100
Consistency77/100
Layer adhesion
Thermal86/100
Best available axisstiffness

Engineering score profile

Overall
72/100
Tensile
Impact
40/100
Stiffness
100/100
Consistency
77/100
Layer adhesion
Thermal
86/100

Engineering radar

TensileImpactStiffnessThermalLayer adhesionConsistency
Selected material
Material average - PA6
Manufacturer average - Eryone

All axes use existing governed 0–100 engineering scores. Missing axes are shown at zero and remain listed as n/a elsewhere in the report.

Fixture thermal result

171 °C · score 86/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall72/10053/10046/100
Tensile44/10025/100
Impact40/10032/10037/100
Stiffness100/10090/10072/100
Consistency77/10073/10074/100
Layer adhesion21/10020/100
Thermal86/100

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright
Tensile flat
Impact upright105.069 kJ/m²25.669 kJ/m²24.4%1010/10
Impact flat695.775 kJ/m²47.255 kJ/m²6.8%1010/10
Stiffness modulus3181.245 MPa
Stiffness deflection1.706 mm

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
TensileNot recorded
Impact2026-08-02
Stiffness2026-08-01
ThermalNot recorded

Engineering interpretation

Summary: Eryone Standard Black PA6 GF Black has a balanced mid-range engineering profile. It is above its material-family average by 19,6 points and above its manufacturer average by 26 points. Its strongest measured axis is Stiffness, while the weakest axis is Impact.
Data-driven review: Eryone Standard Black PA6 GF Black is best understood as a balanced material for general functional prototypes. Compared with the current verified dataset, it ranks better than 100% overall, is above the material-family average by 19,6 points, and is above the manufacturer average by 26 points. Its strongest engineering signal is Stiffness, while Impact is the main limitation to consider before using it for demanding applications.
Best feature
Stiffness
Main limitation
Impact
Dataset position
Better than 100%
2 / 234

Strengths

  • Consistency: 77/100. Repeatability is one of the stronger signals in this material profile.
  • Impact: 40/100. Impact behavior is competitive against the material-family context.
  • Stiffness: 100/100. Stiffness is a relative advantage in this comparison group.

Limitations

  • Main watch item: Impact at 40/100.

Engineering trade-offs

  • Good repeatability does not compensate for low tensile capability in load-bearing designs.
  • Stiffness is useful for shape stability, but impact tolerance is a separate limitation.

Recommended applications

  • Rigid brackets, fixtures and shape-stable prototypes
  • Repeatable print jobs and production-style batches
  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications

Metric rankings and percentiles

MetricScoreRankPercentile
Overall72/1002 / 234Better than 100%
Tensile
Impact40/10049 / 226Better than 79%
Stiffness100/1001 / 223Better than 100%
Consistency77/100137 / 231Better than 41%
Layer adhesion
Thermal86/1001 / 209Better than 100%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpact
No stronger same-base-material alternatives were identified in the current governed dataset.

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpact
MAT0025Extrudr DuraPro PA6 GF BlackExtrudr59/10047/10048/100
MAT0023Extrudr DuraPro PA6 CF BlackExtrudr54/10052/10027/100
MAT0026Yasin Standard Black PA6 GF BlackYasin51/10044/10021/100
MAT0024Yasin Standard Black PA6 CF BlackYasin51/10041/10024/100
MAT0027Yasin Standard Clear PA6 ClearYasin48/10042/10030/100
MAT0212Eryone Standard Black PA6 CF BlackEryone34/10039/100

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.