Public engineering report

Eryone Standard Black ASA CF Black

Material Engineering Report
MaterialID MAT0213
3DPIceland Engineering Platform
3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
Generated 2026-08-25 19:02:26
Public-data contract: This static report contains only allowlisted material identity, public links, canonical MSRP and existing Verified Material Summary / governed score outputs. It excludes raw specimen rows and non-public operational data.
Test coverage
Complete
Engineering axes
6/6
Public MSRP
$17.50 USD/kg

Material identity

MaterialIDMAT0213
MaterialEryone Standard Black ASA CF Black
ManufacturerEryone
Product lineStandard
Base materialASA
CategoryEngineering
Variant / finish
ReinforcementCF
ColorBlack

Governed engineering profile

Overall40/100
Tensile13/100
Impact19/100
Stiffness74/100
Consistency78/100
Layer adhesion16/100
Thermal46/100
Best available axisconsistency

Engineering score profile

Overall
40/100
Tensile
13/100
Impact
19/100
Stiffness
74/100
Consistency
78/100
Layer adhesion
16/100
Thermal
46/100

Engineering radar

TensileImpactStiffnessThermalLayer adhesionConsistency
Selected material
Material average - ASA
Manufacturer average - Eryone

All axes use existing governed 0–100 engineering scores. Missing axes are shown at zero and remain listed as n/a elsewhere in the report.

Fixture thermal result

91 °C · score 46/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall40/10044/10046/100
Tensile13/10019/10025/100
Impact19/10037/10037/100
Stiffness74/10068/10072/100
Consistency78/10076/10074/100
Layer adhesion16/10020/10020/100
Thermal46/100

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright2.884 MPa0.853 MPa29.6%88/10
Tensile flat18.196 MPa7.294 MPa40.1%1010/10
Impact upright115.228 kJ/m²10.653 kJ/m²9.2%1010/10
Impact flat257.483 kJ/m²14.067 kJ/m²5.5%1010/10
Stiffness modulus2223.039 MPa
Stiffness deflection2.441 mm

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
Tensile2026-07-31
Impact2026-08-01
Stiffness2026-07-31
ThermalNot recorded

Engineering interpretation

Summary: Eryone Standard Black ASA CF Black has a specialized or limited engineering profile. It is below its material-family average by 4,2 points and below its manufacturer average by 6,3 points. Its strongest measured axis is Consistency, while the weakest axis is Tensile.
Data-driven review: Eryone Standard Black ASA CF Black is best understood as a repeatable material for cosmetic, concept and low-load prototype work. Compared with the current verified dataset, it ranks better than 14% overall, is below the material-family average by 4,2 points, and is below the manufacturer average by 6,3 points. Its strongest engineering signal is Consistency, while Tensile is the main limitation to consider before using it for demanding applications.
Best feature
Consistency
Main limitation
Tensile
Dataset position
Better than 14%
202 / 234

Strengths

  • Consistency: 78/100. Repeatability is one of the stronger signals in this material profile.
  • Stiffness: 74/100. Stiffness is a relative advantage in this comparison group.

Limitations

  • Tensile: 13/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Impact: 19/100. Avoid high impact or shock-loaded components without additional validation.
  • Layer adhesion: 16/100. Z-axis performance should be treated with caution.

Engineering trade-offs

  • Good repeatability does not compensate for low tensile capability in load-bearing designs.
  • Stiffness is useful for shape stability, but impact tolerance is a separate limitation.
  • The report should be read as a suitability warning rather than a general-purpose recommendation.

Recommended applications

  • Rigid brackets, fixtures and shape-stable prototypes
  • Repeatable print jobs and production-style batches
  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications
  • Avoid high impact components

Metric rankings and percentiles

MetricScoreRankPercentile
Overall40/100202 / 234Better than 14%
Tensile13/100220 / 226Better than 3%
Impact19/100151 / 226Better than 34%
Stiffness74/100128 / 223Better than 43%
Consistency78/100112 / 231Better than 52%
Layer adhesion16/100163 / 226Better than 28%
Thermal46/10021 / 209Better than 90%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpact
MAT0014Extrudr DuraPro Emerald Green ASA GreenExtrudr51/10021/10049/100
MAT0015Prusa3D Prusament ASA Pro GreenPrusa3D48/10023/10044/100
MAT0211Eryone Standard Black ASA High Speed BlackEryone48/10019/10050/100

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpact
MAT0014Extrudr DuraPro Emerald Green ASA GreenExtrudr51/10021/10049/100
MAT0015Prusa3D Prusament ASA Pro GreenPrusa3D48/10023/10044/100
MAT0211Eryone Standard Black ASA High Speed BlackEryone48/10019/10050/100
MAT0016Extrudr DuraPro ASA RedExtrudr48/10019/10050/100
MAT0148Thorwell Standard ASA ASA YellowThorwell46/10022/10056/100
MAT0216Eryone Standard White ASA WhiteEryone46/10023/10051/100
MAT0017Yasin Standard White ASA WhiteYasin46/10021/10051/100
MAT0179BambuLab Standard Blue ASA BlueBambuLab45/10022/10045/100

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.