Rigid test coverage
Partial; 4/5 score families; Izod/Charpy 0/2 measured, 0/2 scored; Overall unavailable: missing measurements or references; policy engineering-score-v70-1
Engineering axes
5/8
Public MSRP
$33.52 USD/kg

Material identity

MaterialIDMAT0224
MaterialSpectrum The Filament Vivid Red PLA Hight Temp Red
ManufacturerSpectrum
Product lineThe Filament
Base materialPLA
CategoryStandard
Variant / finishHight Temp
Reinforcement—
ColorRed

Governed engineering profile

Overall—
Tensile16/100
Impact—
Izod—
Charpy—
Stiffness69/100
Consistency74/100
Layer adhesion12/100
Thermal24/100
Best available axisconsistency

Engineering score profile

Overall
—
Tensile
16/100
Impact
—
Izod
—
Charpy
—
Stiffness
69/100
Consistency
74/100
Layer adhesion
12/100
Thermal
24/100

Engineering radar

TensileLegacy Impact %IzodCharpyStiffnessThermalLayer adhesionConsistency
Selected material
Material average - PLA
Manufacturer average - Spectrum

Legacy Impact radar: 12.908 % of legacy rig capacity. This historical visual reference is the mean corrected Flat/Upright result divided by the matching rig capacity; it is not a modern engineering score.

Izod and Charpy use versioned method references and together form one equally weighted impact family. Overall requires all five families and both calibrated methods; incomplete profiles are not ranked. Legacy Impact and thermal are outside Overall. Missing axes have gaps with no marker or filled polygon; measured zero retains a centre marker.

Fixture thermal result

48 °C · score 24/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall———
Tensile16/10030/10026/100
Impact———
Izod—8/100—
Charpy—10/100—
Stiffness69/10087/10069/100
Consistency74/10075/10065/100
Layer adhesion12/10031/10024/100
Thermal24/100——

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright2.563 MPa0.48 MPa18.7%99/10
Tensile flat22.241 MPa7.154 MPa32.2%1010/10
Impact upright3.632 kJ/m²1.08 kJ/m²29.7%1010/10
Impact flat11.076 kJ/m²2.718 kJ/m²24.5%1010/10
Izod—————
Charpy—————
Stiffness modulus2084.884 MPa————
Stiffness deflection2.603 mm————

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
Tensile2026-08-13
Impact2026-08-13
IzodNot recorded
CharpyNot recorded
Stiffness2026-08-11
Thermal2026-08-14

Engineering interpretation

Summary: Spectrum The Filament Vivid Red PLA Hight Temp Red has a profile awaiting complete scoring evidence. It is without enough material-family average context and without enough manufacturer average context. Its strongest measured axis is Consistency, while the weakest axis is Layer Adhesion.
Data-driven review: Spectrum The Filament Vivid Red PLA Hight Temp Red has incomplete scoring evidence or pending method references. Overall suitability and ranking are unavailable. Available scored axes can be inspected separately; missing scores do not establish weak material performance.
Best feature
Consistency
Main limitation
Layer Adhesion
Dataset position
—
—

Strengths

  • Consistency: 74/100. Repeatability is one of the stronger signals in this material profile.

Limitations

  • Tensile: 16/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Stiffness: 69/100. Expect less shape stability than the stronger materials in the same family.
  • Layer adhesion: 12/100. Z-axis performance should be treated with caution.

Engineering trade-offs

  • Good repeatability does not compensate for low tensile capability in load-bearing designs.

Recommended applications

  • Repeatable print jobs and production-style batches
  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications

Metric rankings and percentiles

MetricScoreRankPercentile
Overall———
Tensile16/100224 / 243Better than 8%
Impact———
Izod———
Charpy———
Stiffness69/100158 / 240Better than 35%
Consistency74/100149 / 243Better than 39%
Layer adhesion12/100201 / 243Better than 18%
Thermal24/100217 / 226Better than 4%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
No stronger same-base-material alternatives were identified in the current governed dataset.

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
MAT0265Coex 3D Standard Scarlet Red PLA RedCoex 3D58/10039/100—n/an/a
MAT0118Prusa3D Prusament Azure Blue PLA BluePrusa3D55/10036/100—n/an/a
MAT0112Prusa3D Prusament Galaxy Black PLA BlackPrusa3D52/10038/100—n/an/a
MAT0143Prusa3D Prusament Corn Pigment PLA Recycled BrownPrusa3D52/10030/100—n/an/a
MAT0203Prusa3D Prusament Prusa Orange PLA OrangePrusa3D52/10042/100—n/an/a
MAT0264Coex 3D Prime Scarlet Red PLA RedCoex 3D52/10034/100—n/an/a
MAT0205Prusa3D Prusament Marble Gray PLA Marble GrayPrusa3D51/10037/100—n/an/a
MAT0204Prusa3D Prusament Jet Black PLA BlackPrusa3D51/10040/100—n/an/a

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.