Public engineering report

Spectrum Premium Iceland Blue PETG Blue

Material Engineering Report
MaterialID MAT0225
3DPIceland Engineering Platform
3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
Generated 2026-10-04 18:07:33
Public-data contract: This static report contains only allowlisted material identity, public links, canonical MSRP and existing Verified Material Summary / governed score outputs. It excludes raw specimen rows and non-public operational data.
Rigid test coverage
Partial; 4/5 score families; Izod/Charpy 0/2 measured, 0/2 scored; Overall unavailable: missing measurements or references; policy engineering-score-v70-1
Engineering axes
5/8
Public MSRP
$35.92 USD/kg

Material identity

MaterialIDMAT0225
MaterialSpectrum Premium Iceland Blue PETG Blue
ManufacturerSpectrum
Product linePremium
Base materialPETG
CategoryStandard
Variant / finish—
Reinforcement—
ColorBlue

Governed engineering profile

Overall—
Tensile33/100
Impact—
Izod—
Charpy—
Stiffness65/100
Consistency70/100
Layer adhesion38/100
Thermal32/100
Best available axisconsistency

Engineering score profile

Overall
—
Tensile
33/100
Impact
—
Izod
—
Charpy
—
Stiffness
65/100
Consistency
70/100
Layer adhesion
38/100
Thermal
32/100

Engineering radar

TensileLegacy Impact %IzodCharpyStiffnessThermalLayer adhesionConsistency
Selected material
Material average - PETG
Manufacturer average - Spectrum

Legacy Impact radar: 14.365 % of legacy rig capacity. This historical visual reference is the mean corrected Flat/Upright result divided by the matching rig capacity; it is not a modern engineering score.

Izod and Charpy use versioned method references and together form one equally weighted impact family. Overall requires all five families and both calibrated methods; incomplete profiles are not ranked. Legacy Impact and thermal are outside Overall. Missing axes have gaps with no marker or filled polygon; measured zero retains a centre marker.

Fixture thermal result

63 °C · score 32/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall———
Tensile33/10028/10026/100
Impact———
Izod—5/100—
Charpy—4/100—
Stiffness65/10060/10069/100
Consistency70/10074/10065/100
Layer adhesion38/10031/10024/100
Thermal32/100——

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright14.335 MPa6.082 MPa42.4%1010/10
Tensile flat37.82 MPa6.45 MPa17.1%99/10
Impact upright9.67 kJ/m²1.777 kJ/m²18.4%1010/10
Impact flat6.699 kJ/m²0.678 kJ/m²10.1%1010/10
Izod—————
Charpy—————
Stiffness modulus1942.234 MPa————
Stiffness deflection2.794 mm————

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
Tensile2026-08-13
Impact2026-08-13
IzodNot recorded
CharpyNot recorded
Stiffness2026-08-11
Thermal2026-08-14

Engineering interpretation

Summary: Spectrum Premium Iceland Blue PETG Blue has a profile awaiting complete scoring evidence. It is without enough material-family average context and without enough manufacturer average context. Its strongest measured axis is Consistency, while the weakest axis is Thermal.
Data-driven review: Spectrum Premium Iceland Blue PETG Blue has incomplete scoring evidence or pending method references. Overall suitability and ranking are unavailable. Available scored axes can be inspected separately; missing scores do not establish weak material performance.
Best feature
Consistency
Main limitation
Thermal
Dataset position
—
—

Strengths

  • Layer adhesion: 38/100. Z-axis bonding is better than the material-family context.

Limitations

  • Tensile: 33/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Layer adhesion: 38/100. Z-axis performance should be treated with caution.

Engineering trade-offs

  • Good repeatability does not compensate for low tensile capability in load-bearing designs.

Recommended applications

  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications

Metric rankings and percentiles

MetricScoreRankPercentile
Overall———
Tensile33/10079 / 243Better than 68%
Impact———
Izod———
Charpy———
Stiffness65/100183 / 240Better than 24%
Consistency70/100180 / 243Better than 26%
Layer adhesion38/10058 / 243Better than 77%
Thermal32/10092 / 226Better than 60%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
No stronger same-base-material alternatives were identified in the current governed dataset.

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
MAT0236Yasin Standard Black PETG CF BlackYasin47/10030/100—n/an/a
MAT0198Siraya Tech Fiberheart Black PETG Pro CF BlackSiraya Tech46/10033/100—n/an/a
MAT0235Yasin Standard Black PETG GF BlackYasin44/10027/100—n/an/a
MAT0048Prusa3D Prusament Jet Black PETG V0 BlackPrusa3D44/10026/100—n/an/a
MAT0042Prusa3D Prusament PETG CF BlackPrusa3D42/10025/100—n/an/a
MAT0043Prima Creator PrimaSelect PETG GF WhitePrima Creator40/10031/100—n/an/a
MAT0266Coex 3D Standard Banana Yellow PETG YellowCoex 3D40/10030/100—n/an/a
MAT0061Prusa3D Prusament Signal White PETG WhitePrusa3D39/10033/100—n/an/a

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.