Rigid test coverage
Complete; 5/5 score families; Izod/Charpy 2/2 measured, 2/2 scored; Overall eligible; policy engineering-score-v70-1
Engineering axes
7/8
Public MSRP
$67.20 USD/kg

Material identity

MaterialIDMAT0231
MaterialYasin Standard Clear PVA Clear
ManufacturerYasin
Product lineStandard
Base materialPVA
CategorySpecialty
Variant / finish—
Reinforcement—
ColorClear

Governed engineering profile

Overall37/100
Tensile6/100
Impact—
Izod8/100
Charpy11/100
Stiffness100/100
Consistency58/100
Layer adhesion11/100
Thermal24/100
Best available axisstiffness

Engineering score profile

Overall
37/100
Tensile
6/100
Impact
—
Izod
8/100
Charpy
11/100
Stiffness
100/100
Consistency
58/100
Layer adhesion
11/100
Thermal
24/100

Engineering radar

TensileLegacy Impact %IzodCharpyStiffnessThermalLayer adhesionConsistency
Selected material
Material average - PVA
Manufacturer average - Yasin

Legacy Impact radar: 22.864 % of legacy rig capacity. This historical visual reference is the mean corrected Flat/Upright result divided by the matching rig capacity; it is not a modern engineering score.

Izod and Charpy use versioned method references and together form one equally weighted impact family. Overall requires all five families and both calibrated methods; incomplete profiles are not ranked. Legacy Impact and thermal are outside Overall. Missing axes have gaps with no marker or filled polygon; measured zero retains a centre marker.

Fixture thermal result

47 °C · score 24/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall37/10037/100—
Tensile6/1006/10025/100
Impact———
Izod8/1008/10011/100
Charpy11/10011/10012/100
Stiffness100/100100/10075/100
Consistency58/10058/10072/100
Layer adhesion11/10011/10019/100
Thermal24/100——

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright1 MPa0.326 MPa32.6%22/10
Tensile flat9.136 MPa5.149 MPa56.4%1010/10
Impact upright2.729 kJ/m²1.087 kJ/m²39.8%99/10
Impact flat23.323 kJ/m²5.597 kJ/m²24%1010/10
Izod6.351 kJ/m²1.112 kJ/m²17.5%1010/10
Charpy8.593 kJ/m²4.095 kJ/m²47.7%1010/10
Stiffness modulus3925.792 MPa————
Stiffness deflection1.382 mm————

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
Tensile2026-08-19
Impact2026-08-20
Izod2026-10-03
Charpy2026-10-03
Stiffness2026-08-18
Thermal2026-08-20

Engineering interpretation

Summary: Yasin Standard Clear PVA Clear has a specialized or limited engineering profile. It is above its material-family average by 0 points and without enough manufacturer average context. Its strongest measured axis is Stiffness, while the weakest axis is Tensile.
Data-driven review: Yasin Standard Clear PVA Clear is best understood as a limited-use material that should be validated carefully before functional use. Compared with the current verified dataset, it ranks better than 13% overall, is roughly aligned with the material-family average, and is missing enough context for the manufacturer average. Its strongest engineering signal is Stiffness, while Tensile is the main limitation to consider before using it for demanding applications.
Best feature
Stiffness
Main limitation
Tensile
Dataset position
Better than 13%
71 / 80

Strengths

  • Stiffness: 100/100. Stiffness is a relative advantage in this comparison group.

Limitations

  • Tensile: 6/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Izod/Charpy impact family: 9/100. Validate impact or shock-loaded components against their application requirements.
  • Layer adhesion: 11/100. Z-axis performance should be treated with caution.

Engineering trade-offs

  • Stiffness is useful for shape stability, but impact tolerance is a separate limitation.
  • The report should be read as a suitability warning rather than a general-purpose recommendation.

Recommended applications

  • Rigid brackets, fixtures and shape-stable prototypes
  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications
  • Avoid high impact components

Metric rankings and percentiles

MetricScoreRankPercentile
Overall37/10071 / 80Better than 13%
Tensile6/100242 / 243Better than 1%
Impact———
Izod8/10041 / 83Better than 52%
Charpy11/10031 / 82Better than 63%
Stiffness100/1001 / 240Better than 100%
Consistency58/100220 / 243Better than 10%
Layer adhesion11/100209 / 243Better than 14%
Thermal24/100221 / 226Better than 3%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
No stronger same-base-material alternatives were identified in the current governed dataset.

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
No same-material peers with governed score context are available.

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 6.351 kJ/m²; Std. Dev 1.112 kJ/m²; CV 17.513%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 8.593 kJ/m²; Std. Dev 4.095 kJ/m²; CV 47.66%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.