Public engineering report

Yasin Standard Black PLA CF Black

Material Engineering Report
MaterialID MAT0234
3DPIceland Engineering Platform
3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
Generated 2026-08-25 19:02:26
Public-data contract: This static report contains only allowlisted material identity, public links, canonical MSRP and existing Verified Material Summary / governed score outputs. It excludes raw specimen rows and non-public operational data.
Test coverage
Complete
Engineering axes
6/6
Public MSRP
$32.56 USD/kg

Material identity

MaterialIDMAT0234
MaterialYasin Standard Black PLA CF Black
ManufacturerYasin
Product lineStandard
Base materialPLA
CategoryStandard
Variant / finish
ReinforcementCF
ColorBlack

Governed engineering profile

Overall44/100
Tensile26/100
Impact24/100
Stiffness86/100
Consistency74/100
Layer adhesion10/100
Thermal24/100
Best available axisstiffness

Engineering score profile

Overall
44/100
Tensile
26/100
Impact
24/100
Stiffness
86/100
Consistency
74/100
Layer adhesion
10/100
Thermal
24/100

Engineering radar

TensileImpactStiffnessThermalLayer adhesionConsistency
Selected material
Material average - PLA
Manufacturer average - Yasin

All axes use existing governed 0–100 engineering scores. Missing axes are shown at zero and remain listed as n/a elsewhere in the report.

Fixture thermal result

47 °C · score 24/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall44/10050/10043/100
Tensile26/10029/10024/100
Impact24/10024/10025/100
Stiffness86/10087/10075/100
Consistency74/10079/10073/100
Layer adhesion10/10030/10019/100
Thermal24/100

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright3.784 MPa2.383 MPa63%1010/10
Tensile flat38.575 MPa6.787 MPa17.6%1010/10
Impact upright151.103 kJ/m²29.079 kJ/m²19.2%1010/10
Impact flat320.163 kJ/m²18.162 kJ/m²5.7%1010/10
Stiffness modulus2580.591 MPa
Stiffness deflection2.103 mm

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
Tensile2026-08-19
Impact2026-08-20
Stiffness2026-08-19
Thermal2026-08-20

Engineering interpretation

Summary: Yasin Standard Black PLA CF Black has a specialized or limited engineering profile. It is below its material-family average by 6,2 points and above its manufacturer average by 0,9 points. Its strongest measured axis is Stiffness, while the weakest axis is Layer Adhesion.
Data-driven review: Yasin Standard Black PLA CF Black is best understood as a repeatable material for cosmetic, concept and low-load prototype work. Compared with the current verified dataset, it ranks better than 32% overall, is below the material-family average by 6,2 points, and is roughly aligned with the manufacturer average. Its strongest engineering signal is Stiffness, while Layer Adhesion is the main limitation to consider before using it for demanding applications.
Best feature
Stiffness
Main limitation
Layer Adhesion
Dataset position
Better than 32%
161 / 234

Strengths

  • Consistency: 74/100. Repeatability is one of the stronger signals in this material profile.
  • Stiffness: 86/100. Stiffness is a relative advantage in this comparison group.

Limitations

  • Tensile: 26/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Impact: 24/100. Avoid high impact or shock-loaded components without additional validation.
  • Layer adhesion: 10/100. Z-axis performance should be treated with caution.

Engineering trade-offs

  • Good repeatability does not compensate for low tensile capability in load-bearing designs.
  • Stiffness is useful for shape stability, but impact tolerance is a separate limitation.
  • The report should be read as a suitability warning rather than a general-purpose recommendation.

Recommended applications

  • Rigid brackets, fixtures and shape-stable prototypes
  • Repeatable print jobs and production-style batches
  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications
  • Avoid high impact components

Metric rankings and percentiles

MetricScoreRankPercentile
Overall44/100161 / 234Better than 32%
Tensile26/100131 / 226Better than 42%
Impact24/100102 / 226Better than 55%
Stiffness86/10090 / 223Better than 60%
Consistency74/100171 / 231Better than 26%
Layer adhesion10/100209 / 226Better than 8%
Thermal24/100205 / 209Better than 2%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpact
MAT0069ProtoPasta HTPLA Blood of My Enemies PLA RedProtoPasta100/100
MAT0079Polymaker PolyLight PLA Pro BlackPolymaker65/10035/10052/100
MAT0109Polymaker PolyMax PLA BlackPolymaker64/10032/10062/100

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpact
MAT0069ProtoPasta HTPLA Blood of My Enemies PLA RedProtoPasta100/100
MAT0079Polymaker PolyLight PLA Pro BlackPolymaker65/10035/10052/100
MAT0109Polymaker PolyMax PLA BlackPolymaker64/10032/10062/100
MAT0080Polymaker PolySonic PLA Pro BluePolymaker64/10030/10058/100
MAT0076BambuLab Tough+ PLA Tough+ BlackBambuLab63/10026/10059/100
MAT0108Polymaker PolyLight PLA BlackPolymaker61/10033/10014/100
MAT0074Winkle Matte PLA Matte RedWinkle60/10034/100
MAT0122Add:North Enhanced PLA ClearAdd:North59/10040/10010/100

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.