Public test session report

Extrudr DuraPro ABS CF Black

MaterialID MAT0002

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-10-02
Charpy2026-10-02
StiffnessNot recorded
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
33
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright0,154 MPa0 MPa0%33/10OK
TensileFlat7,383 MPa2,075 MPa0,281%99/10OK
ImpactUpright4,652 kJ/m²1,442 kJ/m²0,31%1010/10OK
ImpactFlat7,687 kJ/m²0,564 kJ/m²0,073%1010/10OK
StiffnessThree-point bend2795,64 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)1, 1, 1, , , , , , ,
TensileFlat force inputs (N)35, 58, 62, 70, 28, 43, 40, 51, 45,
ImpactUpright needle inputs (%)5,00, 5,00, 7,00, 6,50, 3,00, 5,50, 7,00, 3,00, 7,50, 8,00
ImpactFlat needle inputs (%)10,00, 10,00, 10,00, 9,50, 10,00, 8,00, 9,00, 9,00, 9,00, 10,00
StiffnessRevolutions / degrees1 / 300

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 2.107 kJ/m²; Std. Dev 0.375 kJ/m²; CV 17.807%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 1.912 kJ/m²; Std. Dev 0.232 kJ/m²; CV 12.118%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.