Extrudr DuraPro ABS CF Black
MaterialID MAT0002

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | 2026-10-02 |
| Charpy | 2026-10-02 |
| Stiffness | Not recorded |
Complete
6/6
33
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 0,154 MPa | 0 MPa | 0% | 3 | 3/10 | OK |
| Tensile | Flat | 7,383 MPa | 2,075 MPa | 0,281% | 9 | 9/10 | OK |
| Impact | Upright | 4,652 kJ/m² | 1,442 kJ/m² | 0,31% | 10 | 10/10 | OK |
| Impact | Flat | 7,687 kJ/m² | 0,564 kJ/m² | 0,073% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2795,64 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 1, 1, 1, , , , , , , |
| Tensile | Flat force inputs (N) | 35, 58, 62, 70, 28, 43, 40, 51, 45, |
| Impact | Upright needle inputs (%) | 5,00, 5,00, 7,00, 6,50, 3,00, 5,50, 7,00, 3,00, 7,50, 8,00 |
| Impact | Flat needle inputs (%) | 10,00, 10,00, 10,00, 9,50, 10,00, 8,00, 9,00, 9,00, 9,00, 10,00 |
| Stiffness | Revolutions / degrees | 1 / 300 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 2.107 kJ/m²; Std. Dev 0.375 kJ/m²; CV 17.807%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 1.912 kJ/m²; Std. Dev 0.232 kJ/m²; CV 12.118%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.