Public test session report

Prima Creator PrimaValue Dark Gray ABS Gray

MaterialID MAT0006

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
41
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright7,337 MPa2,779 MPa0,379%1010/10OK
TensileFlat30,669 MPa5,093 MPa0,166%1010/10OK
ImpactUpright138,255 kJ/m²18,975 kJ/m²0,137%1010/10OK
ImpactFlat947,609 kJ/m²42,848 kJ/m²0,045%1010/10OK
StiffnessThree-point bend2223,039 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)45, 63, 22, 46, 13, 46, 58, 70, 52, 62
TensileFlat force inputs (N)145, 218, 199, 231, 231, 141, 226, 194, 191, 218
ImpactUpright needle inputs (%)10,00, 8,00, 7,50, 7,00, 7,00, 7,50, 9,00, 8,00, 8,00, 10,00
ImpactFlat needle inputs (%)62,00, 56,00, 56,00, 65,00, 60,00, 60,00, 57,00, 64,00, 60,00, 67,00
StiffnessRevolutions / degrees2 / 110

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF