Public test session report

Extrudr DuraPro PA6 CF Black

MaterialID MAT0023

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-10-01
Charpy2026-10-01
StiffnessNot recorded
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright25,978 MPa9,326 MPa0,359%1010/10OK
TensileFlat56,986 MPa4,927 MPa0,086%1010/10OK
ImpactUpright5,927 kJ/m²3,288 kJ/m²0,555%1010/10OK
ImpactFlat20,077 kJ/m²3,459 kJ/m²0,172%1010/10OK
StiffnessThree-point bend2250,149 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)176, 235, 99, 202, 230, 220, 115, 220, 86, 106
TensileFlat force inputs (N)397, 388, 404, 348, 392, 319, 338, 395, 391, 333
ImpactUpright needle inputs (%)18,00, 6,50, 4,50, 8,00, 7,00, 7,00, 6,50, 7,00, 4,50, 4,00
ImpactFlat needle inputs (%)21,00, 18,00, 19,00, 23,00, 24,00, 26,00, 28,00, 31,00, 27,00, 28,00
StiffnessRevolutions / degrees2 / 100

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 5.764 kJ/m²; Std. Dev 0.85 kJ/m²; CV 14.749%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 6.103 kJ/m²; Std. Dev 0.927 kJ/m²; CV 15.188%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.