Extrudr DuraPro PA6 GF Black
MaterialID MAT0025

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | 2026-10-04 |
| Charpy | 2026-10-04 |
| Stiffness | Not recorded |
Complete
6/6
40
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 23,225 MPa | 6,22 MPa | 0,268% | 9 | 9/10 | OK |
| Tensile | Flat | 52,679 MPa | 12,074 MPa | 0,229% | 10 | 10/10 | OK |
| Impact | Upright | 13,642 kJ/m² | 1,549 kJ/m² | 0,114% | 10 | 10/10 | OK |
| Impact | Flat | 32,89 kJ/m² | 10,276 kJ/m² | 0,312% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2396,263 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 196, 155, 199, 163, 146, 135, 77, 107, 181, |
| Tensile | Flat force inputs (N) | 400, 377, 261, 333, 394, 397, 374, 401, 158, 330 |
| Impact | Upright needle inputs (%) | 16,50, 18,00, 17,00, 18,00, 18,00, 16,00, 12,50, 19,00, 16,50, 15,00 |
| Impact | Flat needle inputs (%) | 31,00, 34,00, 33,00, 26,00, 64,00, 35,00, 35,00, 35,00, 65,00, 63,00 |
| Stiffness | Revolutions / degrees | 2 / 50 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 5.867 kJ/m²; Std. Dev 0.809 kJ/m²; CV 13.795%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 5.498 kJ/m²; Std. Dev 0.732 kJ/m²; CV 13.314%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.