Public test session report
Yasin Standard Black PA6 GF Black
MaterialID MAT0026

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
41
41
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 7,89 MPa | 2,43 MPa | 0,308% | 10 | 10/10 | OK |
| Tensile | Flat | 63,061 MPa | 13,15 MPa | 0,209% | 10 | 10/10 | OK |
| Impact | Upright | 127,182 kJ/m² | 23,904 kJ/m² | 0,188% | 10 | 10/10 | OK |
| Impact | Flat | 297,668 kJ/m² | 75,787 kJ/m² | 0,255% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2976,004 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 46, 24, 74, 71, 39, 54, 34, 60, 55, 56 |
| Tensile | Flat force inputs (N) | 258, 444, 460, 504, 482, 405, 462, 435, 265, 385 |
| Impact | Upright needle inputs (%) | 6,50, 5,00, 8,00, 7,00, 8,50, 9,00, 6,00, 7,50, 9,00, 9,00 |
| Impact | Flat needle inputs (%) | 14,00, 18,50, 21,00, 19,00, 13,00, 27,00, 18,00, 17,00, 16,00, 11,50 |
| Stiffness | Revolutions / degrees | 1 / 260 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF