Public test session report

Yasin Standard Black PC Plus Black

MaterialID MAT0034

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-10-03
Charpy2026-10-03
StiffnessNot recorded
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
38
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright2,395 MPa1,198 MPa0,5%77/10OK
TensileFlat17,196 MPa5,452 MPa0,317%1010/10OK
ImpactUpright5,633 kJ/m²1,135 kJ/m²0,201%1010/10OK
ImpactFlat14,673 kJ/m²2,047 kJ/m²0,139%1010/10OK
StiffnessThree-point bend1782,727 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)14, 17, 30, 13, 5, 11, 19, , ,
TensileFlat force inputs (N)136, 177, 114, 48, 83, 104, 107, 127, 136, 86
ImpactUpright needle inputs (%)6,00, 7,50, 6,00, 9,00, 5,00, 9,00, 7,00, 6,00, 6,00, 8,00
ImpactFlat needle inputs (%)19,00, 18,00, 21,00, 17,00, 23,00, 16,00, 15,00, 16,00, 17,50, 16,50
StiffnessRevolutions / degrees2 / 315

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 2.989 kJ/m²; Std. Dev 1.03 kJ/m²; CV 34.45%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 4.159 kJ/m²; Std. Dev 0.472 kJ/m²; CV 11.358%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.