Public test session report

Yasin Standard Clear PMMA Clear

MaterialID MAT0035

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
39
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright9,998 MPa3,148 MPa0,315%88/10OK
TensileFlat21,718 MPa5,207 MPa0,24%1010/10OK
ImpactUpright74,612 kJ/m²31,938 kJ/m²0,428%1010/10OK
ImpactFlat545,901 kJ/m²168,401 kJ/m²0,308%1010/10OK
StiffnessThree-point bend887,078 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)69, 102, 64, 87, 45, 44, 54, 55, ,
TensileFlat force inputs (N)110, 107, 130, 116, 159, 107, 154, 143, 207, 179
ImpactUpright needle inputs (%)1,00, 3,00, 3,00, 4,00, 7,00, 4,00, 5,00, 4,50, 6,00, 7,00
ImpactFlat needle inputs (%)40,00, 40,00, 37,00, 14,00, 34,00, 35,00, 13,50, 40,00, 36,00, 35,00
StiffnessRevolutions / degrees5 / 280

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF