Public test session report

3D Fuel PCTG Toolbox Red PCTG Pro GF Red

MaterialID MAT0040

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-10-04
Charpy2026-10-04
StiffnessNot recorded
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
39
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright5,287 MPa2,29 MPa0,433%88/10OK
TensileFlat35,407 MPa3,999 MPa0,113%1010/10OK
ImpactUpright4,936 kJ/m²0,858 kJ/m²0,174%1010/10OK
ImpactFlat24,499 kJ/m²3,185 kJ/m²0,13%1010/10OK
StiffnessThree-point bend1845,122 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)21, 50, 55, 18, 21, 49, 28, 33, ,
TensileFlat force inputs (N)244, 248, 206, 256, 227, 257, 248, 209, 230, 177
ImpactUpright needle inputs (%)6,00, 7,50, 8,00, 6,00, 6,50, 5,50, 6,00, 6,00, 4,50, 5,00
ImpactFlat needle inputs (%)32,00, 26,00, 26,00, 32,00, 35,00, 34,00, 25,00, 25,00, 32,00, 33,00
StiffnessRevolutions / degrees2 / 280

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 10.054 kJ/m²; Std. Dev 0.889 kJ/m²; CV 8.839%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 9.663 kJ/m²; Std. Dev 0.771 kJ/m²; CV 7.974%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.