Public test session report
3D Fuel PCTG Cobalt Blue PCTG Pro Blue
MaterialID MAT0041

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | Not recorded |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
41
41
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 16,058 MPa | 4,492 MPa | 0,28% | 10 | 10/10 | OK |
| Tensile | Flat | 37,56 MPa | 4,709 MPa | 0,125% | 10 | 10/10 | OK |
| Impact | Upright | 3,753 kJ/m² | 0,98 kJ/m² | 0,261% | 10 | 10/10 | OK |
| Impact | Flat | 12,896 kJ/m² | 2,766 kJ/m² | 0,214% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 1512,395 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 128, 79, 85, 90, 131, 136, 93, 135, 117, 50 |
| Tensile | Flat force inputs (N) | 244, 254, 232, 245, 252, 265, 275, 266, 244, 165 |
| Impact | Upright needle inputs (%) | 2,50, 5,00, 3,50, 5,00, 4,00, 4,50, 4,50, 5,00, 5,50, 7,00 |
| Impact | Flat needle inputs (%) | 18,00, 12,00, 17,00, 15,00, 17,00, 17,00, 10,00, 21,00, 12,50, 18,00 |
| Stiffness | Revolutions / degrees | 3 / 140 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF