Public test session report
Prima Creator EasyPrint Solid Black PETG Black
MaterialID MAT0044

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
40
40
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 7,366 MPa | 2,879 MPa | 0,391% | 9 | 9/10 | OK |
| Tensile | Flat | 39,16 MPa | 4,301 MPa | 0,11% | 10 | 10/10 | OK |
| Impact | Upright | 101,688 kJ/m² | 29,8 kJ/m² | 0,293% | 10 | 10/10 | OK |
| Impact | Flat | 261,778 kJ/m² | 32,36 kJ/m² | 0,124% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 1845,122 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 17, 34, 39, 59, 40, 64, 42, 56, 80, |
| Tensile | Flat force inputs (N) | 250, 280, 236, 281, 190, 260, 257, 261, 286, 245 |
| Impact | Upright needle inputs (%) | 3,00, 4,00, 9,50, 6,00, 5,50, 7,00, 6,00, 7,00, 6,00, 6,50 |
| Impact | Flat needle inputs (%) | 13,00, 15,00, 12,00, 17,00, 17,00, 18,00, 14,50, 16,50, 16,00, 15,00 |
| Stiffness | Revolutions / degrees | 2 / 280 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF