Public test session report
IC3D Standard PETG Green
MaterialID MAT0056

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | Not recorded |
Rigid test status
Partial
Partial
Rigid result modules
3/6
3/6
Rigid specimen/result records
35
35
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 11,536 MPa | 3,334 MPa | 0,289% | 10 | 10/10 | OK |
| Tensile | Flat | 30,285 MPa | 2,706 MPa | 0,089% | 10 | 10/10 | OK |
| Impact | Upright | 1,102 kJ/m² | 0,599 kJ/m² | 0,544% | 8 | 8/10 | OK |
| Impact | Flat | 16,793 kJ/m² | 4,642 kJ/m² | 0,276% | 6 | 6/10 | OK |
| Stiffness | Three-point bend | 1205,962 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 60, 96, 61, 87, 82, 112, 64, 52, 45, 91 |
| Tensile | Flat force inputs (N) | 219, 184, 208, 189, 192, 203, 160, 215, 190, 209 |
| Impact | Upright needle inputs (%) | 1,00, 1,00, 1,00, 1,00, 3,00, 1,00, 1,00, 2,00, , |
| Impact | Flat needle inputs (%) | 17,00, 30,00, 18,00, 25,00, 17,00, 16,00, , , , |
| Stiffness | Revolutions / degrees | 4 / 90 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF