Public test session report

Prusa3D Prusament PETG Pro Green

MaterialID MAT0057

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-09-29
Charpy2026-09-29
StiffnessNot recorded
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
39
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright4,422 MPa2,855 MPa0,646%88/10OK
TensileFlat44,989 MPa2,536 MPa0,056%1010/10OK
ImpactUpright4,364 kJ/m²0,788 kJ/m²0,181%1010/10OK
ImpactFlat15,04 kJ/m²3,776 kJ/m²0,251%1010/10OK
StiffnessThree-point bend1708,447 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)68, 9, 29, 30, 11, 38, 22, 23, ,
TensileFlat force inputs (N)292, 298, 305, 296, 306, 309, 254, 301, 285, 279
ImpactUpright needle inputs (%)3,50, 5,00, 5,00, 6,50, 6,00, 5,50, 5,00, 5,50, 7,00, 5,00
ImpactFlat needle inputs (%)22,00, 21,00, 23,00, 12,00, 20,00, 22,00, 12,00, 12,50, 22,00, 17,00
StiffnessRevolutions / degrees3 / 0

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.738 kJ/m²; Std. Dev 0.162 kJ/m²; CV 9.298%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.567 kJ/m²; Std. Dev 0.654 kJ/m²; CV 41.753%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.