Public test session report
ProtoPasta HTPLA Cloverleaf Metallic Green PLA Metal Green
MaterialID MAT0066

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
39
39
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 17,91 MPa | 3,972 MPa | 0,222% | 9 | 9/10 | OK |
| Tensile | Flat | 28,808 MPa | 2,639 MPa | 0,092% | 10 | 10/10 | OK |
| Impact | Upright | 68,834 kJ/m² | 20,563 kJ/m² | 0,299% | 9 | 9/10 | OK |
| Impact | Flat | 116,098 kJ/m² | 18,676 kJ/m² | 0,161% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 3237,057 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 116, 108, 82, 145, 71, 134, 137, 138, 117, |
| Tensile | Flat force inputs (N) | 174, 207, 172, 190, 191, 195, 207, 165, 165, 207 |
| Impact | Upright needle inputs (%) | 6,00, 3,50, 4,00, 2,00, 5,50, 4,50, 4,00, 4,50, 3,00, |
| Impact | Flat needle inputs (%) | 7,00, 7,00, 7,00, 7,00, 4,00, 8,00, 8,00, 7,00, 7,00, 7,00 |
| Stiffness | Revolutions / degrees | 1 / 210 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF