Public test session report
ProtoPasta HTPLA Gloop! Purple PLA Purple
MaterialID MAT0068

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | Not recorded |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
40
40
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 12,705 MPa | 3,836 MPa | 0,302% | 10 | 10/10 | OK |
| Tensile | Flat | 44,348 MPa | 5,583 MPa | 0,126% | 9 | 9/10 | OK |
| Impact | Upright | 7,976 kJ/m² | 1,031 kJ/m² | 0,129% | 10 | 10/10 | OK |
| Impact | Flat | 7,649 kJ/m² | 2,001 kJ/m² | 0,262% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 3354,768 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 99, 75, 61, 38, 101, 74, 79, 128, 73, 98 |
| Tensile | Flat force inputs (N) | 296, 281, 312, 302, 291, 327, 302, 199, 285, |
| Impact | Upright needle inputs (%) | 8,00, 7,50, 11,00, 11,00, 10,00, 10,00, 10,50, 11,00, 10,00, 9,00 |
| Impact | Flat needle inputs (%) | 7,00, 8,00, 10,00, 13,00, 7,50, 14,00, 9,00, 8,50, 7,00, 10,00 |
| Stiffness | Revolutions / degrees | 1 / 190 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF