Public test session report

Prima Creator PrimaSelect Warm Gray PLA Matte Gray

MaterialID MAT0072

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
36
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright2,707 MPa1,453 MPa0,537%55/10OK
TensileFlat26,44 MPa4,948 MPa0,187%1010/10OK
ImpactUpright233,413 kJ/m²12,325 kJ/m²0,053%1010/10OK
ImpactFlat369,751 kJ/m²16,19 kJ/m²0,044%1010/10OK
StiffnessThree-point bend2460,163 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)21, 8, 11, 32, 16, , , , ,
TensileFlat force inputs (N)172, 176, 187, 129, 210, 195, 126, 220, 148, 156
ImpactUpright needle inputs (%)13,00, 13,00, 14,00, 13,00, 14,00, 13,00, 14,00, 14,50, 14,00, 15,00
ImpactFlat needle inputs (%)20,00, 22,00, 20,00, 22,00, 22,00, 22,00, 22,00, 23,00, 22,00, 22,00
StiffnessRevolutions / degrees2 / 30

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF