Public test session report

Prusa3D Buddy3D PLA Silk Gold

MaterialID MAT0086

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
41
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright7,029 MPa2,088 MPa0,297%1010/10OK
TensileFlat33,499 MPa8,741 MPa0,261%1010/10OK
ImpactUpright105,895 kJ/m²19,711 kJ/m²0,186%1010/10OK
ImpactFlat186,208 kJ/m²32,318 kJ/m²0,174%1010/10OK
StiffnessThree-point bend2883,003 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)42, 56, 26, 28, 60, 59, 46, 61, 31, 48
TensileFlat force inputs (N)162, 209, 211, 226, 167, 318, 177, 175, 217, 316
ImpactUpright needle inputs (%)5,00, 6,00, 6,00, 7,00, 5,00, 8,00, 7,00, 8,00, 6,00, 5,00
ImpactFlat needle inputs (%)8,00, 12,00, 13,00, 12,00, 8,00, 10,00, 12,00, 10,00, 12,00, 13,00
StiffnessRevolutions / degrees1 / 280

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF