Public test session report

Polyalchemy Elexir Fire PLA Silk Red

MaterialID MAT0092

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
36
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright2,492 MPa0,831 MPa0,334%55/10OK
TensileFlat25,548 MPa1,147 MPa0,045%1010/10OK
ImpactUpright20,805 kJ/m²13,242 kJ/m²0,636%1010/10OK
ImpactFlat179,058 kJ/m²168,011 kJ/m²0,938%1010/10OK
StiffnessThree-point bend1692,773 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)11, 18, 10, 20, 22, , , , ,
TensileFlat force inputs (N)170, 156, 177, 161, 171, 154, 162, 171, 168, 171
ImpactUpright needle inputs (%)1,00, 1,00, 1,00, 1,00, 3,50, 1,00, 1,00, 1,00, 1,00, 1,00
ImpactFlat needle inputs (%)6,00, 8,00, 8,00, 39,00, 7,00, 9,00, 5,00, 8,00, 8,50, 8,00
StiffnessRevolutions / degrees3 / 10

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF