Public test session report

Yasin Standard Soft PLA PLA Soft White

MaterialID MAT0094

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-10-03
Charpy2026-10-03
StiffnessNot recorded
Rigid test status
Partial
Rigid result modules
4/6
Rigid specimen/result records
39
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright3,623 MPa0,796 MPa0,22%99/10OK
TensileFlat9,751 MPa1,071 MPa0,11%1010/10OK
ImpactUpright7,985 kJ/m²3,67 kJ/m²0,46%1010/10OK
ImpactFlat36,225 kJ/m²3,575 kJ/m²0,099%1010/10OK
StiffnessThree-point bendn/an/an/a0OK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)16, 21, 22, 22, 30, 29, 20, 21, 31,
TensileFlat force inputs (N)64, 67, 64, 66, 65, 68, 67, 44, 64, 65
ImpactUpright needle inputs (%)8,00, 5,50, 15,00, 7,00, 7,00, 14,00, 9,00, 4,50, 10,00, 18,00
ImpactFlat needle inputs (%)51,00, 42,00, 44,00, 44,00, 40,00, 52,00, 37,00, 50,00, 47,00, 50,00
StiffnessRevolutions / degrees

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Flexible Material Testing

Comparative in-house measurements; n = independent specimens. Separate test groups; Overall unchanged.

MethodResultConditionMeannSDCV %RangeNot reached
eaacea91Apparent Compressive Stress at 20% Strain (MPa)10 s hold · 2 mm displacement · cycle 16.262100.1061.6916.099–6.4130
eaacea91Apparent Compressive Stress at 20% Strain (MPa)30 s hold · 2 mm displacement · cycle 16.046100.0951.5715.879–6.1930
eaacea91Compression Force at 20% Strain (N)10 s hold · 2 mm displacement · cycle 1398.4106.7361.691388–4080
eaacea91Compression Force at 20% Strain (N)30 s hold · 2 mm displacement · cycle 1384.6106.0411.571374–3940
eaacea91Force reduction from 10 s to 30 s at 20% Strain (%)first compression only · 2 mm displacement3.462100.3028.7372.813–3.7690
eaacea91Force retention at 20% Strain (%)10–30 s · 2 mm displacement · cycle 196.538100.3020.31396.231–97.1870
eaacea91Residual height loss after recovery (%)20% compression · 30 s compressed hold · 60 s rest · 10 mm initial height · cycle 14.06100.1583.8863.7–4.30
ed381ba8Shore A Hardness (Shore A)10 s reading · 8 mm931——93–930

Shore location statistics

Within each specimen; specimen numbers are local to each test group. SD uses the sample formula. These readings do not increase independent n.

MethodScaleConditionSpecimenReadingsMeanLocation SDLocation CV %
ed381ba8Shore A Hardness10 s reading · 8 mm15932.0312.184

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 39.349 kJ/m²; Std. Dev 3.768 kJ/m²; CV 9.576%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 26.715 kJ/m²; Std. Dev 2.097 kJ/m²; CV 7.851%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.