Public test session report
Prima Creator PrimaValue Black PLA CF Black
MaterialID MAT0098

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | Not recorded |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
40
40
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 5,605 MPa | 2,159 MPa | 0,385% | 9 | 9/10 | OK |
| Tensile | Flat | 39,483 MPa | 5,531 MPa | 0,14% | 10 | 10/10 | OK |
| Impact | Upright | 7,648 kJ/m² | 1,501 kJ/m² | 0,196% | 10 | 10/10 | OK |
| Impact | Flat | 14,136 kJ/m² | 2,314 kJ/m² | 0,164% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2674,09 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 43, 23, 24, 36, 57, 38, 13, 47, 47, |
| Tensile | Flat force inputs (N) | 268, 240, 179, 277, 217, 270, 265, 261, 297, 293 |
| Impact | Upright needle inputs (%) | 12,00, 11,50, 9,50, 10,00, 7,00, 7,00, 10,00, 7,00, 10,00, 10,00 |
| Impact | Flat needle inputs (%) | 18,00, 22,00, 19,00, 13,00, 21,00, 16,00, 15,00, 15,00, 17,00, 16,50 |
| Stiffness | Revolutions / degrees | 1 / 330 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF