Public test session report

Prima Creator PrimaSelect Dark Brown PLA CF Brown

MaterialID MAT0099

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-09-29
CharpyNot recorded
StiffnessNot recorded
Rigid test status
Partial
Rigid result modules
5/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright10,028 MPa4,775 MPa0,476%1010/10OK
TensileFlat39,882 MPa6,847 MPa0,172%1010/10OK
ImpactUpright10,414 kJ/m²1,054 kJ/m²0,101%1010/10OK
ImpactFlat19,851 kJ/m²1,202 kJ/m²0,061%1010/10OK
StiffnessThree-point bend2928,765 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)48, 69, 113, 27, 38, 80, 55, 53, 48, 121
TensileFlat force inputs (N)294, 292, 278, 274, 296, 189, 284, 288, 199, 199
ImpactUpright needle inputs (%)11,00, 13,00, 13,00, 10,00, 13,50, 13,00, 13,00, 14,00, 13,00, 14,00
ImpactFlat needle inputs (%)23,00, 25,00, 23,00, 24,00, 23,00, 25,00, 27,00, 25,00, 22,00, 25,00
StiffnessRevolutions / degrees1 / 270

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 7.155 kJ/m²; Std. Dev 1.038 kJ/m²; CV 14.505%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.