Public test session report

Prima Creator PrimaValue PLA High Speed Gray

MaterialID MAT0101

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
39
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright8,959 MPa3,324 MPa0,371%88/10OK
TensileFlat39,452 MPa3,292 MPa0,083%1010/10OK
ImpactUpright261,776 kJ/m²30,534 kJ/m²0,117%1010/10OK
ImpactFlat967,106 kJ/m²34,274 kJ/m²0,035%1010/10OK
StiffnessThree-point bend2277,929 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)55, 61, 65, 26, 93, 53, 78, 35, ,
TensileFlat force inputs (N)242, 267, 259, 286, 278, 257, 264, 229, 266, 217
ImpactUpright needle inputs (%)15,00, 18,00, 13,00, 13,00, 17,00, 17,00, 15,00, 15,00, 17,00, 14,00
ImpactFlat needle inputs (%)65,00, 66,00, 60,00, 60,00, 65,00, 57,00, 60,00, 66,00, 63,00, 62,00
StiffnessRevolutions / degrees2 / 90

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF