Public test session report

Prusa3D Buddy3D PLA Beige

MaterialID MAT0103

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
IzodNot recorded
CharpyNot recorded
StiffnessNot recorded
Rigid test status
Partial
Rigid result modules
4/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright18,303 MPa5,838 MPa0,319%1010/10OK
TensileFlat40,436 MPa3,977 MPa0,098%1010/10OK
ImpactUpright8,225 kJ/m²1,624 kJ/m²0,197%1010/10OK
ImpactFlat11,862 kJ/m²0,805 kJ/m²0,068%1010/10OK
StiffnessThree-point bend3154,055 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)112, 84, 173, 127, 123, 68, 68, 114, 157, 164
TensileFlat force inputs (N)266, 236, 255, 278, 269, 228, 296, 267, 231, 303
ImpactUpright needle inputs (%)12,00, 7,00, 12,00, 8,00, 8,00, 9,00, 11,00, 12,00, 10,00, 12,00
ImpactFlat needle inputs (%)14,00, 15,00, 15,00, 12,00, 15,00, 15,00, 15,00, 14,00, 15,00, 15,00
StiffnessRevolutions / degrees1 / 225

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF