Public test session report
Prima Creator EasyPrint Black PLA Black
MaterialID MAT0104

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | Not recorded |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
41
41
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 10,459 MPa | 3,284 MPa | 0,314% | 10 | 10/10 | OK |
| Tensile | Flat | 40,805 MPa | 1,914 MPa | 0,047% | 10 | 10/10 | OK |
| Impact | Upright | 7,4 kJ/m² | 1,11 kJ/m² | 0,15% | 10 | 10/10 | OK |
| Impact | Flat | 13,848 kJ/m² | 1,374 kJ/m² | 0,099% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2753,914 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 76, 78, 46, 84, 76, 73, 51, 94, 79, 23 |
| Tensile | Flat force inputs (N) | 240, 259, 265, 259, 261, 278, 283, 260, 273, 275 |
| Impact | Upright needle inputs (%) | 6,00, 9,00, 10,00, 10,00, 10,00, 9,00, 7,50, 9,50, 10,00, 10,00 |
| Impact | Flat needle inputs (%) | 15,00, 16,00, 17,00, 21,00, 16,00, 16,00, 16,00, 18,00, 17,00, 17,00 |
| Stiffness | Revolutions / degrees | 1 / 310 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF