Public test session report
Prima Creator PrimaSelect PLA Tough Black
MaterialID MAT0105

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | Not recorded |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
41
41
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 12,32 MPa | 4,6 MPa | 0,373% | 10 | 10/10 | OK |
| Tensile | Flat | 31,269 MPa | 4,668 MPa | 0,149% | 10 | 10/10 | OK |
| Impact | Upright | 5,675 kJ/m² | 1,52 kJ/m² | 0,268% | 10 | 10/10 | OK |
| Impact | Flat | 52,226 kJ/m² | 4,025 kJ/m² | 0,077% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2170,732 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 105, 114, 103, 50, 43, 62, 86, 37, 86, 115 |
| Tensile | Flat force inputs (N) | 147, 205, 227, 222, 160, 228, 211, 200, 242, 191 |
| Impact | Upright needle inputs (%) | 3,50, 7,00, 7,50, 5,00, 10,00, 7,00, 7,50, 9,00, 7,50, 6,00 |
| Impact | Flat needle inputs (%) | 68,00, 85,00, 62,00, 65,00, 79,00, 95,00, 66,00, 93,00, 72,00, 93,00 |
| Stiffness | Revolutions / degrees | 2 / 130 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF