Public test session report
Polymaker PolyMax PLA Black
MaterialID MAT0109

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
41
41
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 20,964 MPa | 3,725 MPa | 0,178% | 10 | 10/10 | OK |
| Tensile | Flat | 30,1 MPa | 1,725 MPa | 0,057% | 10 | 10/10 | OK |
| Impact | Upright | 188,753 kJ/m² | 17,659 kJ/m² | 0,094% | 10 | 10/10 | OK |
| Impact | Flat | 1041,591 kJ/m² | 73,193 kJ/m² | 0,07% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2027,607 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 130, 141, 104, 119, 103, 121, 164, 156, 164, 161 |
| Tensile | Flat force inputs (N) | 192, 211, 188, 204, 202, 189, 201, 201, 171, 198 |
| Impact | Upright needle inputs (%) | 11,00, 9,50, 11,00, 11,00, 11,00, 11,00, 10,50, 11,00, 13,50, 12,00 |
| Impact | Flat needle inputs (%) | 85,00, 69,00, 82,00, 71,00, 69,00, 57,00, 76,00, 62,00, 70,00, 66,00 |
| Stiffness | Revolutions / degrees | 2 / 190 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF