Public test session report
Add:North Enhanced PLA Green
MaterialID MAT0130

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
41
41
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 19,026 MPa | 5,068 MPa | 0,266% | 10 | 10/10 | OK |
| Tensile | Flat | 40,698 MPa | 2,28 MPa | 0,056% | 10 | 10/10 | OK |
| Impact | Upright | 74,547 kJ/m² | 18,465 kJ/m² | 0,248% | 10 | 10/10 | OK |
| Impact | Flat | 199,055 kJ/m² | 22,264 kJ/m² | 0,112% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2753,914 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 64, 118, 184, 136, 96, 111, 128, 136, 156, 108 |
| Tensile | Flat force inputs (N) | 250, 282, 251, 275, 278, 282, 257, 259, 241, 271 |
| Impact | Upright needle inputs (%) | 4,00, 6,00, 3,00, 4,00, 4,50, 6,50, 4,00, 4,00, 3,50, 5,00 |
| Impact | Flat needle inputs (%) | 11,00, 12,00, 11,00, 10,00, 10,50, 11,50, 14,50, 12,00, 13,00, 12,00 |
| Stiffness | Revolutions / degrees | 1 / 310 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF