Prusa3D Prusament Mistic Green PLA Green
MaterialID MAT0133

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | 2026-10-02 |
| Charpy | 2026-10-02 |
| Stiffness | Not recorded |
Complete
6/6
41
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 16,181 MPa | 4,459 MPa | 0,276% | 10 | 10/10 | OK |
| Tensile | Flat | 44,42 MPa | 5,654 MPa | 0,127% | 10 | 10/10 | OK |
| Impact | Upright | 7,111 kJ/m² | 0,895 kJ/m² | 0,126% | 10 | 10/10 | OK |
| Impact | Flat | 14,262 kJ/m² | 1,416 kJ/m² | 0,099% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2976,004 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 122, 161, 76, 77, 129, 130, 75, 99, 89, 94 |
| Tensile | Flat force inputs (N) | 308, 262, 283, 286, 301, 330, 276, 299, 336, 207 |
| Impact | Upright needle inputs (%) | 9,00, 10,00, 8,00, 7,50, 9,00, 8,00, 9,00, 8,00, 11,00, 8,00 |
| Impact | Flat needle inputs (%) | 18,00, 19,00, 19,00, 18,00, 20,00, 15,00, 15,00, 17,00, 16,00, 17,00 |
| Stiffness | Revolutions / degrees | 1 / 260 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 7.042 kJ/m²; Std. Dev 9.988 kJ/m²; CV 141.822%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 3.421 kJ/m²; Std. Dev 0.234 kJ/m²; CV 6.83%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.