Public test session report

Add:North Enhanced PLA Natural

MaterialID MAT0134

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
IzodNot recorded
CharpyNot recorded
StiffnessNot recorded
Rigid test status
Partial
Rigid result modules
2/6
Rigid specimen/result records
40
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright24,163 MPa2,838 MPa0,117%1010/10OK
TensileFlat39,882 MPa1,646 MPa0,041%1010/10OK
ImpactUpright2,17 kJ/m²0,341 kJ/m²0,157%1010/10OK
ImpactFlat7,935 kJ/m²0,759 kJ/m²0,096%1010/10OK
StiffnessThree-point bendn/an/an/a0OK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)155, 166, 152, 111, 153, 172, 162, 153, 176, 171
TensileFlat force inputs (N)277, 263, 246, 271, 264, 253, 261, 264, 247, 247
ImpactUpright needle inputs (%)2,00, 3,00, 3,00, 2,00, 3,00, 2,50, 3,00, 3,00, 2,50, 3,00
ImpactFlat needle inputs (%)11,00, 8,00, 9,50, 11,00, 10,00, 10,00, 9,00, 10,00, 10,00, 9,00
StiffnessRevolutions / degrees

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF