Public test session report

Yasin Standard Wood PLA Wood Wood Brown

MaterialID MAT0145

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
37
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright3,512 MPa1,24 MPa0,353%66/10OK
TensileFlat27,009 MPa4,879 MPa0,181%1010/10OK
ImpactUpright125,525 kJ/m²35,295 kJ/m²0,281%1010/10OK
ImpactFlat266,077 kJ/m²17,209 kJ/m²0,065%1010/10OK
StiffnessThree-point bend2306,403 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)32, 26, 31, 14, 20, 14, , , ,
TensileFlat force inputs (N)161, 201, 192, 181, 166, 136, 203, 112, 197, 207
ImpactUpright needle inputs (%)5,00, 4,00, 5,00, 7,00, 8,00, 9,00, 8,50, 9,50, 9,00, 9,50
ImpactFlat needle inputs (%)14,50, 16,00, 15,00, 15,00, 15,00, 15,00, 16,00, 18,00, 16,00, 16,00
StiffnessRevolutions / degrees2 / 80

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF