Public test session report

Thorwell Standard Silk PLA Silk Blue

MaterialID MAT0147

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
37
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright3,23 MPa1,088 MPa0,337%66/10OK
TensileFlat15,319 MPa3,633 MPa0,237%1010/10OK
ImpactUpright68,743 kJ/m²37,198 kJ/m²0,541%1010/10OK
ImpactFlat212,835 kJ/m²42,48 kJ/m²0,2%1010/10OK
StiffnessThree-point bend1299,382 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)23, 20, 9, 21, 22, 31, , , ,
TensileFlat force inputs (N)74, 118, 115, 48, 115, 112, 86, 116, 96, 116
ImpactUpright needle inputs (%)1,00, 4,00, 4,50, 7,00, 1,00, 1,50, 5,00, 6,50, 5,50, 5,00
ImpactFlat needle inputs (%)13,00, 13,00, 15,00, 13,50, 14,00, 14,00, 14,00, 8,00, 13,00, 8,00
StiffnessRevolutions / degrees3 / 340

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF