Public test session report
Thorwell Standard PLA White
MaterialID MAT0155

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
40
40
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 13,627 MPa | 3,374 MPa | 0,248% | 10 | 10/10 | OK |
| Tensile | Flat | 44,543 MPa | 10,192 MPa | 0,229% | 10 | 10/10 | OK |
| Impact | Upright | 150,981 kJ/m² | 21,984 kJ/m² | 0,146% | 9 | 9/10 | OK |
| Impact | Flat | 235,136 kJ/m² | 22,933 kJ/m² | 0,098% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2976,004 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 47, 113, 93, 102, 108, 67, 104, 105, 74, 73 |
| Tensile | Flat force inputs (N) | 358, 369, 275, 329, 229, 344, 265, 293, 150, 284 |
| Impact | Upright needle inputs (%) | 7,00, 8,00, 9,00, 10,00, 8,00, 11,00, 9,50, 8,00, 10,00, |
| Impact | Flat needle inputs (%) | 13,00, 14,00, 14,00, 14,50, 14,00, 13,00, 11,00, 15,00, 14,00, 16,00 |
| Stiffness | Revolutions / degrees | 1 / 260 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF