Public test session report
Winkle Standard Smokey Gray PLA Matte Gray
MaterialID MAT0158

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
41
41
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 7,49 MPa | 2,36 MPa | 0,315% | 10 | 10/10 | OK |
| Tensile | Flat | 33,884 MPa | 6,338 MPa | 0,187% | 10 | 10/10 | OK |
| Impact | Upright | 133,129 kJ/m² | 15,459 kJ/m² | 0,116% | 10 | 10/10 | OK |
| Impact | Flat | 706,673 kJ/m² | 33,165 kJ/m² | 0,047% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 1962,896 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 49, 46, 46, 48, 68, 55, 60, 26, 67, 22 |
| Tensile | Flat force inputs (N) | 140, 252, 261, 196, 195, 247, 256, 234, 247, 175 |
| Impact | Upright needle inputs (%) | 6,00, 7,50, 8,00, 8,00, 8,50, 9,00, 9,00, 8,00, 7,00, 8,00 |
| Impact | Flat needle inputs (%) | 42,00, 39,00, 41,00, 43,00, 44,00, 43,00, 43,00, 40,00, 43,00, 47,00 |
| Stiffness | Revolutions / degrees | 2 / 220 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF