BambuLab Basic PET CF Black
MaterialID MAT0166

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | 2026-10-04 |
| Charpy | 2026-10-04 |
| Stiffness | Not recorded |
Complete
6/6
41
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 5,845 MPa | 3,547 MPa | 0,607% | 10 | 10/10 | OK |
| Tensile | Flat | 34,438 MPa | 5,842 MPa | 0,17% | 10 | 10/10 | OK |
| Impact | Upright | 3,758 kJ/m² | 1,819 kJ/m² | 0,484% | 10 | 10/10 | OK |
| Impact | Flat | 16,448 kJ/m² | 1,558 kJ/m² | 0,095% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2976,004 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 23, 71, 25, 68, 69, 29, 22, 6, 29, 38 |
| Tensile | Flat force inputs (N) | 180, 217, 253, 179, 236, 266, 181, 264, 195, 268 |
| Impact | Upright needle inputs (%) | 2, 1, 3,5, 3,5, 4, 5,5, 6,5, 8, 5,5, 7 |
| Impact | Flat needle inputs (%) | 20, 18, 18,5, 18, 23, 22, 22, 20, 18, 21 |
| Stiffness | Revolutions / degrees | 1 / 260 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 6.482 kJ/m²; Std. Dev 0.353 kJ/m²; CV 5.441%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 5.734 kJ/m²; Std. Dev 0.223 kJ/m²; CV 3.884%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.