Public test session report

BambuLab Basic PA12 PAHT CF Black

MaterialID MAT0167

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-10-04
Charpy2026-10-04
StiffnessNot recorded
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright5,045 MPa2,367 MPa0,469%1010/10OK
TensileFlat56,663 MPa9,575 MPa0,169%1010/10OK
ImpactUpright6,329 kJ/m²0,648 kJ/m²0,102%1010/10OK
ImpactFlat33,13 kJ/m²2,76 kJ/m²0,083%1010/10OK
StiffnessThree-point bend2598,764 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)46, 17, 49, 30, 47, 9, 20, 34, 53, 23
TensileFlat force inputs (N)411, 371, 357, 389, 395, 202, 418, 387, 353, 401
ImpactUpright needle inputs (%)9, 7,5, 6,5, 7,5, 8, 8, 9, 7,5, 8, 7
ImpactFlat needle inputs (%)44, 40, 36, 38, 49, 45, 39, 42, 39, 41
StiffnessRevolutions / degrees1 / 350

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 17.214 kJ/m²; Std. Dev 0.625 kJ/m²; CV 3.632%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 16.462 kJ/m²; Std. Dev 0.508 kJ/m²; CV 3.085%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.