Public test session report

BambuLab Standard Indigo Blue PETG CF Blue

MaterialID MAT0170

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-09-30
Charpy2026-09-30
StiffnessNot recorded
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
38
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright4,597 MPa2,757 MPa0,6%99/10OK
TensileFlat29,435 MPa6,919 MPa0,235%88/10OK
ImpactUpright4,326 kJ/m²1,428 kJ/m²0,33%1010/10OK
ImpactFlat23,299 kJ/m²6,449 kJ/m²0,277%1010/10OK
StiffnessThree-point bend1604,454 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)14, 18, 41, 20, 11, 61, 24, 26, 54,
TensileFlat force inputs (N)199, 198, 202, 222, 214, 202, 82, 212, ,
ImpactUpright needle inputs (%)5, 4,5, 6,5, 7,5, 4, 3, 7,5, 3,5, 7,5, 4,5
ImpactFlat needle inputs (%)22, 32, 15, 29, 32, 39, 27, 41, 29, 20
StiffnessRevolutions / degrees3 / 70

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 5.338 kJ/m²; Std. Dev 0.525 kJ/m²; CV 9.838%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 4.612 kJ/m²; Std. Dev 0.969 kJ/m²; CV 21.008%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.