Public test session report
BambuLab Standard Blue ASA Blue
MaterialID MAT0179

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | Not recorded |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
40
40
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 3,452 MPa | 2,39 MPa | 0,692% | 9 | 9/10 | OK |
| Tensile | Flat | 32,3 MPa | 5,328 MPa | 0,165% | 10 | 10/10 | OK |
| Impact | Upright | 4,691 kJ/m² | 0,908 kJ/m² | 0,193% | 10 | 10/10 | OK |
| Impact | Flat | 39,02 kJ/m² | 1,381 kJ/m² | 0,035% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2196,574 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 7, 5, 33, 11, 46, 41, 10, 18, 31, |
| Tensile | Flat force inputs (N) | 252, 249, 150, 184, 176, 191, 229, 220, 245, 204 |
| Impact | Upright needle inputs (%) | 5, 6, 7,5, 7, 5, 7, 5,5, 5, 6, 4 |
| Impact | Flat needle inputs (%) | 50, 50, 46, 51, 50, 50, 51, 51, 52, 46 |
| Stiffness | Revolutions / degrees | 2 / 120 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF