Public test session report
Sunlu Standard Blue PLA High Speed Blue
MaterialID MAT0182

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | Not recorded |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
41
41
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 10,136 MPa | 3,025 MPa | 0,298% | 10 | 10/10 | OK |
| Tensile | Flat | 43,912 MPa | 2,008 MPa | 0,046% | 10 | 10/10 | OK |
| Impact | Upright | 6,207 kJ/m² | 0,967 kJ/m² | 0,156% | 10 | 10/10 | OK |
| Impact | Flat | 14,138 kJ/m² | 0,878 kJ/m² | 0,062% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 3354,768 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 47, 44, 90, 77, 80, 75, 31, 84, 73, 58 |
| Tensile | Flat force inputs (N) | 286, 300, 257, 291, 275, 289, 295, 284, 300, 278 |
| Impact | Upright needle inputs (%) | 5, 6,5, 7, 8,5, 8, 8,5, 8, 8, 8, 9 |
| Impact | Flat needle inputs (%) | 17,5, 16, 15, 18,5, 17, 18, 18,, 18, 17, 17,5 |
| Stiffness | Revolutions / degrees | 1 / 190 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF