Public test session report
Elegoo Standard Sky Blue PLA Plus Blue
MaterialID MAT0192

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | Not recorded |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
41
41
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 13,212 MPa | 3,391 MPa | 0,257% | 10 | 10/10 | OK |
| Tensile | Flat | 43,112 MPa | 2,637 MPa | 0,061% | 10 | 10/10 | OK |
| Impact | Upright | 8,595 kJ/m² | 1,14 kJ/m² | 0,133% | 10 | 10/10 | OK |
| Impact | Flat | 19,924 kJ/m² | 4,917 kJ/m² | 0,247% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2158,038 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 91, 120, 87, 57, 103, 59, 91, 89, 56, 106 |
| Tensile | Flat force inputs (N) | 274, 303, 278, 289, 259, 301, 280, 295, 273, 251 |
| Impact | Upright needle inputs (%) | 11, 11, 11,5, 10, 10, 7, 11, 11, 11, 12 |
| Impact | Flat needle inputs (%) | 33, 30, 20, 20, 20, 22, 35, 22, 17,5, 24 |
| Stiffness | Revolutions / degrees | 2 / 135 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF